Abstract This study aims at experimentally investigating the hydrodynamic behavior of a centrifugal pump, both with and without cavitation. The pump consists of an axial inducer, a centrifugal impeller, and a volute. Three assembly configurations are examined: the inducer alone, the impeller alone, and the combined inducer and impeller. Particular attention is given to cavitating conditions—low suction pressure—at four partial flowrates (4% ϕref, 16% ϕref, 39% ϕref, and 78% ϕref), where ϕref is defined as the flow coefficient for which the inducer has been designed. The hydromechanical performance is analyzed and compared across these configurations, with cavitation formation captured using high-speed digital imaging. A spectral analysis of pressure signals is also conducted in operational regimes where instabilities were observed. The results indicate that the inducer mitigates the impact of cavitation on hydromechanical performance as the flowrate approaches the design point ϕref. However, at partial flowrates, the inducer negatively impacts pump performance by increasing the critical cavitation number threshold beyond which a head drop occurs. Cavitation-induced instabilities were observed in partial flow regimes and under low suction pressure conditions in configurations involving the inducer. These instabilities, characterized by a very low-frequency signature, result in significant pressure and flow fluctuations, leading to vibrations within the system. Furthermore, these instabilities exhibit a clear dependency on flowrate.

Authors

Institutions

Publication Details

Journal
Journal of Fluids Engineering
Published
2025-03-07
DOI
https://doi.org/10.1115/1.4068132
Citations
4
Primary Topic
Cavitation Phenomena in Pumps
Type
article
Field-Weighted Citation Impact
3.45
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Comparison of Hydrodynamic Behavior Under Partial Flowrates and Cavitation in Three Configurations of a Centrifugal Pump With Inducer and Impeller

Petar Tomov, Farid Bakir, Loic Pora, Florent Ravelet et al.
4 citations
Journal of Fluids Engineering
Cavitation Phenomena in Pumps
3.45
article

Experimental Comparison of Hydrodynamic Behavior Under Partial Flowrates and Cavitation in Three Configurations of a Centrifugal Pump With Inducer and Impeller

Petar Tomov, Farid Bakir, Loic Pora, Florent Ravelet, Gilles Brun, Victor Gentis, Michael P. Pereira
article en
4 citations

Abstract

Abstract This study aims at experimentally investigating the hydrodynamic behavior of a centrifugal pump, both with and without cavitation. The pump consists of an axial inducer, a centrifugal impeller, and a volute. Three assembly configurations are examined: the inducer alone, the impeller alone, and the combined inducer and impeller. Particular attention is given to cavitating conditions—low suction pressure—at four partial flowrates (4% ϕref, 16% ϕref, 39% ϕref, and 78% ϕref), where ϕref is defined as the flow coefficient for which the inducer has been designed. The hydromechanical performance is analyzed and compared across these configurations, with cavitation formation captured using high-speed digital imaging. A spectral analysis of pressure signals is also conducted in operational regimes where instabilities were observed. The results indicate that the inducer mitigates the impact of cavitation on hydromechanical performance as the flowrate approaches the design point ϕref. However, at partial flowrates, the inducer negatively impacts pump performance by increasing the critical cavitation number threshold beyond which a head drop occurs. Cavitation-induced instabilities were observed in partial flow regimes and under low suction pressure conditions in configurations involving the inducer. These instabilities, characterized by a very low-frequency signature, result in significant pressure and flow fluctuations, leading to vibrations within the system. Furthermore, these instabilities exhibit a clear dependency on flowrate.

Journal of Fluids EngineeringVol. 147(9)
Conservatoire National des Arts et Métiers (FR), Arts et Métiers (FR), Safran Electronics (Canada) (CA), Safran (France) (FR)
Openalex Percentile: Top 9%
Cavitation Phenomena in Pumps
3.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.