An Uncommon Deformity of the Collarless, Polished, Double-Taper (CPT) Stem After a Periprosthetic Fracture in Total Hip Arthroplasty

We present an uncommon case of a Collarless, Polished, Double-Taper (CPT) stem deformity (irreversible stem bending) occurring due to a Periprosthetic Fracture (PPF) in Total Hip Arthroplasty (THA). The entire course of the case, including treatment, risk factors, and failure analysis of the deformed CPT by its manufacturer, Zimmer Biomet (Warsaw, USA),is described. The discussion considers in detail the (risk) factors that led to this particular stem deformity, incorporating current literature. We conclude with learning points on how to prevent stem abnormalities in PPFs in the future. In our case, there were some case-specific risk factors associated with bending of the CPT stem. These factors are a relative varus angle, relative under-sizing of the stem, and a potentially inadequate cement mantle around the primary stem. No material or manufacture failure of the stem could be found. Still, it is very unusual that the femoral stem deforms without fracturing. Taken together, we present a unique case of a Periprosthetic Fracture with CPT stem deformity following Total Hip Arthroplasty.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-03-07
DOI
https://doi.org/10.7759/cureus.80197
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Uncommon Deformity of the Collarless, Polished, Double-Taper (CPT) Stem After a Periprosthetic Fracture in Total Hip Arthroplasty

Bert Boonen, Thijs A Nijenhuis, Julia E J W Geilen, Isobel M. Dorling
1 links
Cureus
Orthopaedic implants and arthroplasty
article

An Uncommon Deformity of the Collarless, Polished, Double-Taper (CPT) Stem After a Periprosthetic Fracture in Total Hip Arthroplasty

Bert Boonen, Thijs A Nijenhuis, Julia E J W Geilen, Isobel M. Dorling
article en

Abstract

We present an uncommon case of a Collarless, Polished, Double-Taper (CPT) stem deformity (irreversible stem bending) occurring due to a Periprosthetic Fracture (PPF) in Total Hip Arthroplasty (THA). The entire course of the case, including treatment, risk factors, and failure analysis of the deformed CPT by its manufacturer, Zimmer Biomet (Warsaw, USA),is described. The discussion considers in detail the (risk) factors that led to this particular stem deformity, incorporating current literature. We conclude with learning points on how to prevent stem abnormalities in PPFs in the future. In our case, there were some case-specific risk factors associated with bending of the CPT stem. These factors are a relative varus angle, relative under-sizing of the stem, and a potentially inadequate cement mantle around the primary stem. No material or manufacture failure of the stem could be found. Still, it is very unusual that the femoral stem deforms without fracturing. Taken together, we present a unique case of a Periprosthetic Fracture with CPT stem deformity following Total Hip Arthroplasty.

CureusVol. 17(3)
Streekziekenhuis Koningin Beatrix (NL), Zuyderland Medisch Centrum (NL)
Openalex Percentile: Top 93%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.