Evaluation of the effect of monochromatic images of Ti6Al4V implant material obtained with Dual Energy CT on radiotherapy plans using the Treatment Planning System and EGSnrc Monte Carlo simulation

This study aimed to evaluate the effect of Dual Energy Computed Tomography (DECT) imaging on radiotherapy planning for Ti6Al4V (grade 23), a high-density implant material, using the Treatment Planning System (TPS) and Monte Carlo (MC) simulation. For this purpose, Ti6Al4V implants with diameters of 6.4 mm and 28 mm were produced with a 3D printer and placed in a Cheese phantom. Single Energy Computed Tomography (SECT) and DECT images were obtained for each implant. SECT and DECT plans were created using TPS on SECT and DECT images and DECT plans were simulated using the EGSnrc-based BEAM nrc MC code system. SECT images of the Cheese phantom consisting entirely of water were transferred to TPS and artefact-free reference plans were created by virtually creating implants in planning. The obtained planning and simulation results were compared with the reference plan and dose errors in planning were determined. As a result of the study, it was observed that DECT imaging significantly increased the dose accuracy for the 6.4 mm diameter TI6Al4V implant compared to conventional planning. For the 28 mm diameter implant material, it was observed that DECT imaging decreased the success of artefact suppression, but significantly increased the dose accuracy in treatment planning. It was observed that DECT scanners could be used for simulation purposes in radiotherapy clinics for patients with Ti6Al4V implant material. The study needs to be extended to other high-density implant materials encountered in patients receiving radiotherapy.

Authors

Institutions

Publication Details

Journal
International Journal of Computational and Experimental Science and Engineering
Published
2025-03-06
DOI
https://doi.org/10.22399/ijcesen.918
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the effect of monochromatic images of Ti6Al4V implant material obtained with Dual Energy CT on radiotherapy plans using the Treatment Planning System and EGSnrc Monte Carlo simulation

Türkay Toklu, E Onal, Bahar Dırıcan
International Journal of Computational and Experimental Science and Engineering
Advanced X-ray and CT Imaging
article

Evaluation of the effect of monochromatic images of Ti6Al4V implant material obtained with Dual Energy CT on radiotherapy plans using the Treatment Planning System and EGSnrc Monte Carlo simulation

Türkay Toklu, E Onal, Bahar Dırıcan
article en

Abstract

This study aimed to evaluate the effect of Dual Energy Computed Tomography (DECT) imaging on radiotherapy planning for Ti6Al4V (grade 23), a high-density implant material, using the Treatment Planning System (TPS) and Monte Carlo (MC) simulation. For this purpose, Ti6Al4V implants with diameters of 6.4 mm and 28 mm were produced with a 3D printer and placed in a Cheese phantom. Single Energy Computed Tomography (SECT) and DECT images were obtained for each implant. SECT and DECT plans were created using TPS on SECT and DECT images and DECT plans were simulated using the EGSnrc-based BEAM nrc MC code system. SECT images of the Cheese phantom consisting entirely of water were transferred to TPS and artefact-free reference plans were created by virtually creating implants in planning. The obtained planning and simulation results were compared with the reference plan and dose errors in planning were determined. As a result of the study, it was observed that DECT imaging significantly increased the dose accuracy for the 6.4 mm diameter TI6Al4V implant compared to conventional planning. For the 28 mm diameter implant material, it was observed that DECT imaging decreased the success of artefact suppression, but significantly increased the dose accuracy in treatment planning. It was observed that DECT scanners could be used for simulation purposes in radiotherapy clinics for patients with Ti6Al4V implant material. The study needs to be extended to other high-density implant materials encountered in patients receiving radiotherapy.

International Journal of Computational and Experimental Science and EngineeringVol. 11(1)
University of Health Sciences Antigua (AG)
Openalex Percentile: Top 96%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of the effect of monochromatic images of Ti6Al4V implant material obtained with Dual Energy CT on radiotherapy plans using the Treatment Planning System and EGSnrc Monte Carlo simulation — Türkay Toklu, E Onal, et al. · International Journal of Computational and Experimental Science and Engineering (2025) | TGRS Research Map | TGRS