Electron polarimetry at EIC

The Electron-Ion Collider will be the first collider to use both polarized electron beams and polarized protons and light ions . This will offer unique opportunities to study the structure of protons and nuclei and answer fundamental questions in QCD. The uncertainties on the polarization measurement translate directly into the uncertainties of final physics observables. Hence, a precise measurement of the hadron beam polarization and a good control of the uncertainties are critical for the success of the spin program at the EIC. The requirements for beam polarimetry are non-destructive with uncertainty less than 1%. At the Electron Storage Ring (ESR) and the Rapid Cycling Synchrotron (RCS), the electron beam polarization will be measured using well-established Compton polarimetry techniques. However, the EIC Compton polarimeter will face unique challenges, demanding further developments. A Mott polarimeter will also be employed at the source for initial polarization measurements. Both longitudinal and transverse polarization will be measured, with the capability to monitor polarization on a bunch-by-bunch basis. Achieving these precise measurements will be critical to controlling systematic uncertainties and ensuring the overall success of the EIC’s physics objectives.

Authors

Publication Details

Published
2025-03-07
DOI
https://doi.org/10.22323/1.472.0019
Primary Topic
Electron and X-Ray Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electron polarimetry at EIC

Dave Gaskell, Zhengqiao Zhang, Elke-Caroline Aschenauer
Electron and X-Ray Spectroscopy Techniques
article

Electron polarimetry at EIC

Dave Gaskell, Zhengqiao Zhang, Elke-Caroline Aschenauer
article en

Abstract

The Electron-Ion Collider will be the first collider to use both polarized electron beams and polarized protons and light ions . This will offer unique opportunities to study the structure of protons and nuclei and answer fundamental questions in QCD. The uncertainties on the polarization measurement translate directly into the uncertainties of final physics observables. Hence, a precise measurement of the hadron beam polarization and a good control of the uncertainties are critical for the success of the spin program at the EIC. The requirements for beam polarimetry are non-destructive with uncertainty less than 1%. At the Electron Storage Ring (ESR) and the Rapid Cycling Synchrotron (RCS), the electron beam polarization will be measured using well-established Compton polarimetry techniques. However, the EIC Compton polarimeter will face unique challenges, demanding further developments. A Mott polarimeter will also be employed at the source for initial polarization measurements. Both longitudinal and transverse polarization will be measured, with the capability to monitor polarization on a bunch-by-bunch basis. Achieving these precise measurements will be critical to controlling systematic uncertainties and ensuring the overall success of the EIC’s physics objectives.

Openalex Percentile: Top 96%
Electron and X-Ray Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.