Vacuum-plasma transition effect on positron acceleration in the bubble regime plasma wakefield accelerators

In recent years, the field of positron acceleration in plasma wakefield accelerators has witnessed rapid theoretical advancements, and several effective schemes have been proposed. In these studies, longitudinally uniform plasma is taken into account, with the positron beam located at the start of the second wakefield bubble. The electron filament near the positron beam provides Coulomb attraction force for the guiding of the positron beam. However, the influence of vacuum-plasma transition on positron beams has not been considered yet, where wakefield bubble is larger than that in the density plateau region, and the positron beam is in the defocusing region. In this paper, we study the evolution of positron beam size in the vacuum-plasma transition region and find out that the transition is detrimental to low-energy positron beams. Wide drive beams with relatively large transverse sizes are proposed as a possible solution to this difficulty.

Authors

Institutions

Publication Details

Journal
Physical Review Accelerators and Beams
Published
2025-03-07
DOI
https://doi.org/10.1103/physrevaccelbeams.28.031301
Citations
1
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
1.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vacuum-plasma transition effect on positron acceleration in the bubble regime plasma wakefield accelerators

Jie Gao, Dazhang Li, Jia Wang, Ming Zeng
1 citations
Physical Review Accelerators and Beams
Laser-Plasma Interactions and Diagnostics
1.87
article

Vacuum-plasma transition effect on positron acceleration in the bubble regime plasma wakefield accelerators

Jie Gao, Dazhang Li, Jia Wang, Ming Zeng
article en
1 citations

Abstract

In recent years, the field of positron acceleration in plasma wakefield accelerators has witnessed rapid theoretical advancements, and several effective schemes have been proposed. In these studies, longitudinally uniform plasma is taken into account, with the positron beam located at the start of the second wakefield bubble. The electron filament near the positron beam provides Coulomb attraction force for the guiding of the positron beam. However, the influence of vacuum-plasma transition on positron beams has not been considered yet, where wakefield bubble is larger than that in the density plateau region, and the positron beam is in the defocusing region. In this paper, we study the evolution of positron beam size in the vacuum-plasma transition region and find out that the transition is detrimental to low-energy positron beams. Wide drive beams with relatively large transverse sizes are proposed as a possible solution to this difficulty.

Physical Review Accelerators and BeamsVol. 28(3)
Chinese Academy of Sciences (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, Chinese Academy of Sciences, Institute of High Energy Physics, National Key Research and Development Program of China
Openalex Percentile: Top 15%
Laser-Plasma Interactions and Diagnostics
1.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.