Two photoacoustic spectral coloring compensation techniques adapted to the context of human <i>in-vivo</i> oxygenation measurements

Photoacoustic imaging can potentially map oxygen saturation (sO 2 ) non-invasively. However, in-vivo human application is challenging due to spectral coloring, which causes a wavelength-dependent fluence attenuation and uncertainty in the estimation of chromophore concentrations deep in tissue. This study compares the performances of two previously proposed methods for spectral coloring compensation on in-vivo human data. Both methods have been modified and adapted to this context. The first modified method was evaluated using a tissue-mimicking phantom, showing restoration of the original spectrum of the target and decreasing the relative mean square error from 65% to 1.2% for the highest concentration. Spatial maps of sO 2 were estimated from in-vivo human finger measurements using both methods and compared with linear unmixing. Both methods reconstructed comparable values of sO 2 and reduced depth-dependent changes in sO 2 , typically seen with linear unmixing, resulting in a gradient of saturation closer to zero as expected physiologically.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-03-07
DOI
https://doi.org/10.1364/boe.555305
Citations
1
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two photoacoustic spectral coloring compensation techniques adapted to the context of human in-vivo oxygenation measurements

Aboma Merdasa, Baptiste Jayet, Rafi Sheikh, Malin Malmsjö et al.
1 citations
Biomedical Optics Express
Photoacoustic and Ultrasonic Imaging
0.67
article

Two photoacoustic spectral coloring compensation techniques adapted to the context of human in-vivo oxygenation measurements

Aboma Merdasa, Baptiste Jayet, Rafi Sheikh, Malin Malmsjö, John Albinsson, Azin Khodaverdi, Magnus Cinthio, Stefan Andersson‐Engels, Tobias Erlöv, Nils Gustafsson
article en
1 citations

Abstract

Photoacoustic imaging can potentially map oxygen saturation (sO 2 ) non-invasively. However, in-vivo human application is challenging due to spectral coloring, which causes a wavelength-dependent fluence attenuation and uncertainty in the estimation of chromophore concentrations deep in tissue. This study compares the performances of two previously proposed methods for spectral coloring compensation on in-vivo human data. Both methods have been modified and adapted to this context. The first modified method was evaluated using a tissue-mimicking phantom, showing restoration of the original spectrum of the target and decreasing the relative mean square error from 65% to 1.2% for the highest concentration. Spatial maps of sO 2 were estimated from in-vivo human finger measurements using both methods and compared with linear unmixing. Both methods reconstructed comparable values of sO 2 and reduced depth-dependent changes in sO 2 , typically seen with linear unmixing, resulting in a gradient of saturation closer to zero as expected physiologically.

Biomedical Optics ExpressVol. 16(6)
University College Cork (IE)
Openalex Percentile: Top 34%
Photoacoustic and Ultrasonic Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.