Two Approaches to Determining the Shower Size Threshold of a Small EAS Array

We compared two methods for determining the detector performance and the cosmic ray small-surface array aperture. The comparison was performed using the GELATICA network station at Telavi Iakob Gogebashvili State University (hereafter TEL) as an example. The first method is a standard analytical method. It is based on mean values of variables and averaged distributions. This analytical approach to data analysis was the focus of the research carried out within the GELATICA project. The project is a member of the international CREDO (Cosmic-Ray Extremely Distributed Observatory) Collaboration, whose main goal is the detection and global analysis of cosmic ray ensembles. In contrast to the traditional approach, which focuses on the detection of individual cosmic ray extensive air showers, CREDO aims to connect existing and yet-to-be built cosmic ray arrays into a worldwide network, thus creating a scientific tool for the global analysis of ultra-high energy cosmic rays. The present work was the first to compare the determination of the parameters of the extensive air showers recorded by the TEL array with simulation results using the CORSIKA code. The interpretation of the results of the analytical method for the evaluation of detector registration thresholds is generally found to be inconclusive. In order to obtain definitive results, we propose additional measurements and a new method of array detector performance. We show that the energy spectrum obtained analytically is nearly in agreement with that obtained from simulations. Differences are apparent for the primary particle energy threshold. The difference in the overall counting rate for the TEL array is of the order of 4%.

Authors

Institutions

Publication Details

Journal
Symmetry
Published
2025-03-07
DOI
https://doi.org/10.3390/sym17030403
Primary Topic
Electromagnetic Compatibility and Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two Approaches to Determining the Shower Size Threshold of a Small EAS Array

M. Svanidze, Tadeusz Wibig, Revaz Beradze, V. Kikvadze et al.
Symmetry
Electromagnetic Compatibility and Measurements
article

Two Approaches to Determining the Shower Size Threshold of a Small EAS Array

M. Svanidze, Tadeusz Wibig, Revaz Beradze, V. Kikvadze, Abesalom Iashvili, I. Iashvili
article en

Abstract

We compared two methods for determining the detector performance and the cosmic ray small-surface array aperture. The comparison was performed using the GELATICA network station at Telavi Iakob Gogebashvili State University (hereafter TEL) as an example. The first method is a standard analytical method. It is based on mean values of variables and averaged distributions. This analytical approach to data analysis was the focus of the research carried out within the GELATICA project. The project is a member of the international CREDO (Cosmic-Ray Extremely Distributed Observatory) Collaboration, whose main goal is the detection and global analysis of cosmic ray ensembles. In contrast to the traditional approach, which focuses on the detection of individual cosmic ray extensive air showers, CREDO aims to connect existing and yet-to-be built cosmic ray arrays into a worldwide network, thus creating a scientific tool for the global analysis of ultra-high energy cosmic rays. The present work was the first to compare the determination of the parameters of the extensive air showers recorded by the TEL array with simulation results using the CORSIKA code. The interpretation of the results of the analytical method for the evaluation of detector registration thresholds is generally found to be inconclusive. In order to obtain definitive results, we propose additional measurements and a new method of array detector performance. We show that the energy spectrum obtained analytically is nearly in agreement with that obtained from simulations. Differences are apparent for the primary particle energy threshold. The difference in the overall counting rate for the TEL array is of the order of 4%.

SymmetryVol. 17(3)
Tbilisi State University (GE), University of Łódź (PL), University at Buffalo, State University of New York (US)
Openalex Percentile: Top 97%
Electromagnetic Compatibility and Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.