Resolving the Orientations of and Angular Separation Between a Pair of Dipole Emitters

We prove that it is impossible to distinguish two spatially coinciding fluorescent molecules from a single rotating molecule using polarization-sensitive imaging, even if one modulates the polarization of the illumination or the detection dipole-spread function (DSF). If the target is known to be a dipole pair, existing imaging methods perform poorly for measuring their angular separation. We propose simultaneously modulating the excitation polarization and DSF, which demonstrates robust discrimination between dipole pairs versus single molecules. Our method improves the precision of measuring centroid orientation by 50% and angular separation by two- to four-fold over existing techniques.

Authors

Institutions

Publication Details

Journal
Physical Review Letters
Published
2025-03-07
DOI
https://doi.org/10.1103/physrevlett.134.093805
Citations
5
Primary Topic
Near-Field Optical Microscopy
Type
article
Field-Weighted Citation Impact
3.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resolving the Orientations of and Angular Separation Between a Pair of Dipole Emitters

Matthew D. Lew, Y. N. Chen, Yuanxin Qiu
5 citations
Physical Review Letters
Near-Field Optical Microscopy
3.37
article

Resolving the Orientations of and Angular Separation Between a Pair of Dipole Emitters

Matthew D. Lew, Y. N. Chen, Yuanxin Qiu
article en
5 citations

Abstract

We prove that it is impossible to distinguish two spatially coinciding fluorescent molecules from a single rotating molecule using polarization-sensitive imaging, even if one modulates the polarization of the illumination or the detection dipole-spread function (DSF). If the target is known to be a dipole pair, existing imaging methods perform poorly for measuring their angular separation. We propose simultaneously modulating the excitation polarization and DSF, which demonstrates robust discrimination between dipole pairs versus single molecules. Our method improves the precision of measuring centroid orientation by 50% and angular separation by two- to four-fold over existing techniques.

Physical Review LettersVol. 134(9)
Washington University in St. Louis (US)
National Institutes of Health, National Institute of General Medical Sciences
Openalex Percentile: Top 9%
Near-Field Optical Microscopy
3.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.