Measurement of axial dose profile for wide detector CT using radiochromic films

To investigate the application of radiochromic film LD-V1 for measuring the dose profile of wide detector CT and comparing the measurements with the console-displayed CTDI<sub>vol</sub>, with the aim of obtaining correction factors. Calibration curves in CTDI phantoms were first obtained with various tube currents at 120 kV. Then, at the selected wide beam collimations (80, 100, 120, 140, 160 mm), the film was placed in the extended phantom holes to obtain the dose profile. CTDI was calculated for different integration intervals, which allowed obtaining the CTDI<sub>100</sub> measurement efficiency. Finally, the CTDI<sub>vol,300</sub> measured was compared to the console-displayed CTDI<sub>vol</sub>, and corresponding correction factors were derived. The discrepancy between the CTDI<sub>100</sub> obtained by the calibration curve and ionization chamber was essentially in the range of -8-4%. The CTDI<sub>100</sub> measurement efficiency was found to decrease with increasing beam widths. Furthermore, under selected wide beam collimations (80, 100, 120, 140, 160 mm), the correction factors in the head phantom were 1.299, 1.284, 1.157, 1.151, 1.099; 1.566, 1.585, 1.512, 1.365, 1.327 in the body phantom, respectively. Radiochromic film LD-V1 is feasible for measuring the dose profile of a wide detector CT scanner. The console-displayed CTDI<sub>vol</sub> doesn't provide a full assessment of the radiation dose. It is recommended that the correction factors obtained in this study be used to improve the accuracy for evaluating the radiation dose to the subject.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-07
DOI
https://doi.org/10.1038/s41598-025-91681-x
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of axial dose profile for wide detector CT using radiochromic films

Baohui Liang, Jing Wang, Mengting Wang, Qi Sun et al.
Scientific Reports
Radiation Dose and Imaging
article

Measurement of axial dose profile for wide detector CT using radiochromic films

Baohui Liang, Jing Wang, Mengting Wang, Qi Sun, Yihan Fan, Qin Tian
article en

Abstract

To investigate the application of radiochromic film LD-V1 for measuring the dose profile of wide detector CT and comparing the measurements with the console-displayed CTDI<sub>vol</sub>, with the aim of obtaining correction factors. Calibration curves in CTDI phantoms were first obtained with various tube currents at 120 kV. Then, at the selected wide beam collimations (80, 100, 120, 140, 160 mm), the film was placed in the extended phantom holes to obtain the dose profile. CTDI was calculated for different integration intervals, which allowed obtaining the CTDI<sub>100</sub> measurement efficiency. Finally, the CTDI<sub>vol,300</sub> measured was compared to the console-displayed CTDI<sub>vol</sub>, and corresponding correction factors were derived. The discrepancy between the CTDI<sub>100</sub> obtained by the calibration curve and ionization chamber was essentially in the range of -8-4%. The CTDI<sub>100</sub> measurement efficiency was found to decrease with increasing beam widths. Furthermore, under selected wide beam collimations (80, 100, 120, 140, 160 mm), the correction factors in the head phantom were 1.299, 1.284, 1.157, 1.151, 1.099; 1.566, 1.585, 1.512, 1.365, 1.327 in the body phantom, respectively. Radiochromic film LD-V1 is feasible for measuring the dose profile of a wide detector CT scanner. The console-displayed CTDI<sub>vol</sub> doesn't provide a full assessment of the radiation dose. It is recommended that the correction factors obtained in this study be used to improve the accuracy for evaluating the radiation dose to the subject.

Scientific ReportsVol. 15(1)
Bengbu Medical College (CN), Anhui Medical University (CN), Second Affiliated Hospital of Anhui Medical University (CN), First Affiliated Hospital of Bengbu Medical College (CN)
Openalex Percentile: Top 94%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.