A novel moving phantom insert for image quality assessment in magnetic resonance imaging

Dedicated motion compensated Magnetic Resonance Imaging (MRI) for radiotherapy treatment planning promises to mitigate motion effects on imaging. We demonstrate a novel insert for an MRI safe motion phantom, which enables quality assurance of these image strategies. The capability to analyse apparent slice thickness, positional accuracy and motion blur is demonstrated for scenarios with and without motion. A respiratory-compensated scan with a 4 mm trigger-window and 16 mm peak-to-peak (p2p) motion showed a +5.0% deviation from the nominal 2 mm slice thickness. In contrast, a non-compensated scan with 4 mm p2p motion showed a +77.5% deviation, illustrating the effectiveness of motion compensation.

Authors

Institutions

Publication Details

Journal
Physics and Imaging in Radiation Oncology
Published
2025-03-07
DOI
https://doi.org/10.1016/j.phro.2025.100742
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel moving phantom insert for image quality assessment in magnetic resonance imaging

Cornelis A. T. van den Berg, Martin F. Fast, Pim Borman, Astrid L.H.M.W. van Lier et al.
Physics and Imaging in Radiation Oncology
Advanced Radiotherapy Techniques
article

A novel moving phantom insert for image quality assessment in magnetic resonance imaging

Cornelis A. T. van den Berg, Martin F. Fast, Pim Borman, Astrid L.H.M.W. van Lier, Frédérique P. D. van Gameren, Mike Cole, Grant R. Koenig
article en

Abstract

Dedicated motion compensated Magnetic Resonance Imaging (MRI) for radiotherapy treatment planning promises to mitigate motion effects on imaging. We demonstrate a novel insert for an MRI safe motion phantom, which enables quality assurance of these image strategies. The capability to analyse apparent slice thickness, positional accuracy and motion blur is demonstrated for scenarios with and without motion. A respiratory-compensated scan with a 4 mm trigger-window and 16 mm peak-to-peak (p2p) motion showed a +5.0% deviation from the nominal 2 mm slice thickness. In contrast, a non-compensated scan with 4 mm p2p motion showed a +77.5% deviation, illustrating the effectiveness of motion compensation.

Physics and Imaging in Radiation OncologyVol. 34
University Medical Center Utrecht (NL)
Openalex Percentile: Top 95%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.