Chest freezer with integrated heat exchanger for augmenting the COP

The study analyzes the performances of a modified chest freezer with a heat exchanger. The experiments are performed on the chest freezer to analyze the impact of baffles of various geometries placed inside the heat exchanger on the freezer's coefficient of performance. To remove the thermal energy the refrigerant before condensation phase, water is used as a coolant in the heat exchanger. Baffles with four different profiles were used for the analyses and they were baffles with sextant geometry, sextant profile with holes, strip cuts, and internal sextant cuts. Experiments are performed with various water mass flow rates and for different product loads. Further experiments are conducted for to analyze the performance of chest freezer for increase in number of baffles inside the heat exchanger. Experimental results indicate that the segmental baffles having sextant profiles with internal sextant cuts showed the best performance in terms of COP and low irreversibility. The coefficient of performance increased from 0.9 to 0.1 when conventional VCR systems were integrated with heat exchangers having six numbers of inserts and keeping the mass flow rate at 0.43 kg/s. The proposed VCR saw a reduction of 10% consumes in power consumption compared to conventional VCR.

Authors

Institutions

Publication Details

Journal
International Journal of Thermofluids
Published
2025-03-07
DOI
https://doi.org/10.1016/j.ijft.2025.101157
Citations
2
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Chest freezer with integrated heat exchanger for augmenting the COP

R. Venkatesan, K. Srithar, R. Saravanan, S. Abishai Immanuel et al.
2 citations
International Journal of Thermofluids
Refrigeration and Air Conditioning Technologies
1.43
article

Chest freezer with integrated heat exchanger for augmenting the COP

R. Venkatesan, K. Srithar, R. Saravanan, S. Abishai Immanuel, M. Krishkarna
article en
2 citations

Abstract

The study analyzes the performances of a modified chest freezer with a heat exchanger. The experiments are performed on the chest freezer to analyze the impact of baffles of various geometries placed inside the heat exchanger on the freezer's coefficient of performance. To remove the thermal energy the refrigerant before condensation phase, water is used as a coolant in the heat exchanger. Baffles with four different profiles were used for the analyses and they were baffles with sextant geometry, sextant profile with holes, strip cuts, and internal sextant cuts. Experiments are performed with various water mass flow rates and for different product loads. Further experiments are conducted for to analyze the performance of chest freezer for increase in number of baffles inside the heat exchanger. Experimental results indicate that the segmental baffles having sextant profiles with internal sextant cuts showed the best performance in terms of COP and low irreversibility. The coefficient of performance increased from 0.9 to 0.1 when conventional VCR systems were integrated with heat exchangers having six numbers of inserts and keeping the mass flow rate at 0.43 kg/s. The proposed VCR saw a reduction of 10% consumes in power consumption compared to conventional VCR.

International Journal of ThermofluidsVol. 27
Madurai Medical College (IN), Anna University, Chennai (IN)
Affordable and clean energy
Openalex Percentile: Top 22%
Refrigeration and Air Conditioning Technologies
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Chest freezer with integrated heat exchanger for augmenting the COP — R. Venkatesan, K. Srithar, et al. · International Journal of Thermofluids (2025) | TGRS Research Map | TGRS