A cutting-edge design of a novel electrochemical voltammetric nanosensor modified with molecularly imprinted polymer along with multi-walled carbon nanotubes for selective safinamide recognition

• A selective molecular imprinted polymer was fabricated for Safinamide recognition. • Novel carbon paste electrode modified with MIP along with MWCNTs for enhanced performance. • The established voltammetric method exhibited high sensitivity with a nano-detection limit. • Successful sensor application for Safinamide determination in various real samples. • Method's sustainability was ascertained via adopting smart metric tools. Safinamide mesylate (SAF) is an innovative adjuvant treatment for managing wearing-off symptoms in Parkinson's disease (PD). Our novel approach involves the development of a differential pulse voltammetric (DPV) technique for SAF determination. This method utilizes a carbon nanocomposite paste electrode that is modified by a molecularly imprinted polymer (MIP) to serve as a recognition element for SAF. Additionally, multi-walled carbon nanotubes (MWCNTs) are incorporated to enhance the electrode's sensitivity. The MIP was subjected to a thorough characterization process, including analysis of rebinding, differential scanning calorimetry, field emission scanning electron microscopy, and Fourier-transform infrared spectroscopy. The cavities of the MIP recognize and bind to the medication, functioning as reliable host-tailored artificial receptors. The resulting modified electrode functions as a voltammetric sensor, enabling the nano detection of SAF. The fabricated MIP/MWCNTs-CPE demonstrates a linear range from 0.3 to 22.0 μg/mL and excellent sensitivity, with a limit of detection (LOD) of 0.079 μg/mL. According to ICH guidelines, the enhanced method has been validated for quality control testing on the pharmaceutical product and spiked human plasma. The proposed method was found to be practical, reliable, cost-effective, and efficient means of estimating the investigated drug. The method's sustainability was assessed by analyzing its scores for greenness, blueness, and whiteness. Therefore, this method has the potential to be a long-term, practical analytical tool for in vitro studies and quality control laboratories.

Authors

Institutions

Publication Details

Journal
Talanta Open
Published
2025-03-07
DOI
https://doi.org/10.1016/j.talo.2025.100428
Citations
3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A cutting-edge design of a novel electrochemical voltammetric nanosensor modified with molecularly imprinted polymer along with multi-walled carbon nanotubes for selective safinamide recognition

Laila Abdel-Fattah, Maha A. Hegazy, Samah S. Saad, Engy A. Ibrahim et al.
3 citations
Talanta Open
Electrochemical sensors and biosensors
2.19
article

A cutting-edge design of a novel electrochemical voltammetric nanosensor modified with molecularly imprinted polymer along with multi-walled carbon nanotubes for selective safinamide recognition

Laila Abdel-Fattah, Maha A. Hegazy, Samah S. Saad, Engy A. Ibrahim, Hoda M. Marzouk
article en
3 citations

Abstract

• A selective molecular imprinted polymer was fabricated for Safinamide recognition. • Novel carbon paste electrode modified with MIP along with MWCNTs for enhanced performance. • The established voltammetric method exhibited high sensitivity with a nano-detection limit. • Successful sensor application for Safinamide determination in various real samples. • Method's sustainability was ascertained via adopting smart metric tools. Safinamide mesylate (SAF) is an innovative adjuvant treatment for managing wearing-off symptoms in Parkinson's disease (PD). Our novel approach involves the development of a differential pulse voltammetric (DPV) technique for SAF determination. This method utilizes a carbon nanocomposite paste electrode that is modified by a molecularly imprinted polymer (MIP) to serve as a recognition element for SAF. Additionally, multi-walled carbon nanotubes (MWCNTs) are incorporated to enhance the electrode's sensitivity. The MIP was subjected to a thorough characterization process, including analysis of rebinding, differential scanning calorimetry, field emission scanning electron microscopy, and Fourier-transform infrared spectroscopy. The cavities of the MIP recognize and bind to the medication, functioning as reliable host-tailored artificial receptors. The resulting modified electrode functions as a voltammetric sensor, enabling the nano detection of SAF. The fabricated MIP/MWCNTs-CPE demonstrates a linear range from 0.3 to 22.0 μg/mL and excellent sensitivity, with a limit of detection (LOD) of 0.079 μg/mL. According to ICH guidelines, the enhanced method has been validated for quality control testing on the pharmaceutical product and spiked human plasma. The proposed method was found to be practical, reliable, cost-effective, and efficient means of estimating the investigated drug. The method's sustainability was assessed by analyzing its scores for greenness, blueness, and whiteness. Therefore, this method has the potential to be a long-term, practical analytical tool for in vitro studies and quality control laboratories.

Talanta OpenVol. 11
Cairo University (EG), Misr University for Science and Technology (EG), Future University in Egypt (EG)
Openalex Percentile: Top 13%
Electrochemical sensors and biosensors
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.