A Convenient Calibration Method for Robot Hand Eye System Without External Calibration Objects

For the hand eye system calibration problem of inspection robot equipped with dual robotic arms and RGB-D camera, a simplified joint calibration method based on deep learning is proposed. It eliminates the need for external systems and calibration boards, resolving the calibration of the dual robotic arms and the extrinsic calibration of the RGB-D camera within the hand eye system of the inspection robot. By utilizing nonlinear optimization, it effectively reduces measurement noise and minimizes the propagation and influence of calibration errors in the coordinate transformation. Experimental results demonstrate that the proposed method achieves an average calibration error of 0.5mm for the dual robotic arms, and a minimum calibration error of 1.2mm for the camera's extrinsic parameters. Consequently, it significantly enhances the hand eye localization accuracy of the inspection robot during task execution. The innovative approach holds promising potential for improving the practical application of inspection robots.

Authors

Institutions

Publication Details

Published
2024-12-10
DOI
https://doi.org/10.1109/robio64047.2024.10907708
Primary Topic
Industrial Vision Systems and Defect Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Convenient Calibration Method for Robot Hand Eye System Without External Calibration Objects

Juntai Zhang, Fan Yang, Yuan Ji, Wei Zhou et al.
Industrial Vision Systems and Defect Detection
article

A Convenient Calibration Method for Robot Hand Eye System Without External Calibration Objects

Juntai Zhang, Fan Yang, Yuan Ji, Wei Zhou, Kai He, Cui Ma
article en

Abstract

For the hand eye system calibration problem of inspection robot equipped with dual robotic arms and RGB-D camera, a simplified joint calibration method based on deep learning is proposed. It eliminates the need for external systems and calibration boards, resolving the calibration of the dual robotic arms and the extrinsic calibration of the RGB-D camera within the hand eye system of the inspection robot. By utilizing nonlinear optimization, it effectively reduces measurement noise and minimizes the propagation and influence of calibration errors in the coordinate transformation. Experimental results demonstrate that the proposed method achieves an average calibration error of 0.5mm for the dual robotic arms, and a minimum calibration error of 1.2mm for the camera's extrinsic parameters. Consequently, it significantly enhances the hand eye localization accuracy of the inspection robot during task execution. The innovative approach holds promising potential for improving the practical application of inspection robots.

Chinese Academy of Sciences (CN), Shenzhen Institutes of Advanced Technology (CN)
Openalex Percentile: Top 59%
Industrial Vision Systems and Defect Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.