Towards 3D Reconstruction With Variable-Baseline Binocular Endoscope for Minimally Invasive Surgery

Binocular endoscopy is widely used in minimally invasive surgery due to the easy acquisition of three-dimensional (3D) information. However, there are still limitations such as reduced precision in specific depth scenarios. To address the deficiency, we introduce a novel binocular endoscope reconstruction method with a variable baseline, which is founded upon the utilization of a multi-arm concentric-tube robot. First, the poses of two endoscopes with variable baselines can be obtained by modified ORB-SLAM3 algorithm. Then, the 3D structure can be reconstructed using the improved semi-global matching (SGM) algorithm based on two endoscopic images with known relative poses. Finally, to quantitatively calculate the reconstruction error, the experiment employs a method of co-reconstruction with a chessboard to indirectly measure the error. The result shows that the proposed method can effectively improve the accuracy of 3D reconstruction while maintaining real-time performance.

Authors

Institutions

Publication Details

Published
2024-12-10
DOI
https://doi.org/10.1109/robio64047.2024.10907645
Citations
1
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards 3D Reconstruction With Variable-Baseline Binocular Endoscope for Minimally Invasive Surgery

Jinrui Cui, Jiaole Wang, Tiantian Wang, Chao Zhang et al.
1 citations
Surgical Simulation and Training
0.57
article

Towards 3D Reconstruction With Variable-Baseline Binocular Endoscope for Minimally Invasive Surgery

Jinrui Cui, Jiaole Wang, Tiantian Wang, Chao Zhang, Shuang Song
article en
1 citations

Abstract

Binocular endoscopy is widely used in minimally invasive surgery due to the easy acquisition of three-dimensional (3D) information. However, there are still limitations such as reduced precision in specific depth scenarios. To address the deficiency, we introduce a novel binocular endoscope reconstruction method with a variable baseline, which is founded upon the utilization of a multi-arm concentric-tube robot. First, the poses of two endoscopes with variable baselines can be obtained by modified ORB-SLAM3 algorithm. Then, the 3D structure can be reconstructed using the improved semi-global matching (SGM) algorithm based on two endoscopic images with known relative poses. Finally, to quantitatively calculate the reconstruction error, the experiment employs a method of co-reconstruction with a chessboard to indirectly measure the error. The result shows that the proposed method can effectively improve the accuracy of 3D reconstruction while maintaining real-time performance.

Harbin Institute of Technology (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 26%
Surgical Simulation and Training
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Towards 3D Reconstruction With Variable-Baseline Binocular Endoscope for Minimally Invasive Surgery — Jinrui Cui, Jiaole Wang, et al. · (2024) | TGRS Research Map | TGRS