A Real-Time Detection Algorithm for Electrocardiogram and Arterial Blood Pressure Signals in Intra-Aortic Balloon Pump

This paper proposes an algorithm combining a dynamic adaptive thresholding R-wave detection strategy and a differential feature-based blood pressure waveform recognition technique to realize rapid and real-time electrocardiogram (ECG) and arterial blood pressure (ABP) signal detection. The aim is to address the demand for accuracy and real-time performance of the intra-aortic balloon pump (IABP) system in heart failure treatment as an adjunct to heart failure. The proposed algorithm was validated in two public databases: the MIT-BIH arrhythmia database (MITDB) and the polysomnography database (SLPDB). The results showed that the sensitivity and positive predictive value of the ECG R-wave detection were 97.51 % and 99.73%, respectively, while the accuracy of the blood pressure feature point detection could reach 99.18%. Furthermore, the real-time performance of the algorithm was also evaluated, and the algorithm's detection average lead time was +0.46 milliseconds. In summary, this algorithm provides effective help for IABP timing technology and shows good application potential in the field of mechanical circulation-assisted therapy of cardiovascular diseases.

Authors

Institutions

Publication Details

Published
2024-10-26
DOI
https://doi.org/10.1109/cisp-bmei64163.2024.10906083
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Real-Time Detection Algorithm for Electrocardiogram and Arterial Blood Pressure Signals in Intra-Aortic Balloon Pump

Jian Wu, Shiqi Yu, Lepeng Zeng
Fault Detection and Control Systems
article

A Real-Time Detection Algorithm for Electrocardiogram and Arterial Blood Pressure Signals in Intra-Aortic Balloon Pump

Jian Wu, Shiqi Yu, Lepeng Zeng
article en

Abstract

This paper proposes an algorithm combining a dynamic adaptive thresholding R-wave detection strategy and a differential feature-based blood pressure waveform recognition technique to realize rapid and real-time electrocardiogram (ECG) and arterial blood pressure (ABP) signal detection. The aim is to address the demand for accuracy and real-time performance of the intra-aortic balloon pump (IABP) system in heart failure treatment as an adjunct to heart failure. The proposed algorithm was validated in two public databases: the MIT-BIH arrhythmia database (MITDB) and the polysomnography database (SLPDB). The results showed that the sensitivity and positive predictive value of the ECG R-wave detection were 97.51 % and 99.73%, respectively, while the accuracy of the blood pressure feature point detection could reach 99.18%. Furthermore, the real-time performance of the algorithm was also evaluated, and the algorithm's detection average lead time was +0.46 milliseconds. In summary, this algorithm provides effective help for IABP timing technology and shows good application potential in the field of mechanical circulation-assisted therapy of cardiovascular diseases.

Lifetech Scientific (China) (CN), Tsinghua–Berkeley Shenzhen Institute (CN)
Good health and well-being
Openalex Percentile: Top 65%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Real-Time Detection Algorithm for Electrocardiogram and Arterial Blood Pressure Signals in Intra-Aortic Balloon Pump — Jian Wu, Shiqi Yu, et al. · (2024) | TGRS Research Map | TGRS