Evaluation of 6 MV photon beam characteristics on Varian Clinac iX: a Monte Carlo study

This work aims to study the characteristics of photon beams through phase space file (PSF) analysis using Monte Carlo (MC) simulation. 6 MV photon beams from the Varian Clinac iX were simulated using PRIMO software. The beam parameters were validated by evaluating the percentage depth dose and dose profile. A full PSF was scored at the downstream end of the linear accelerator (LINAC) upper and lower parts and analyzed to determine the beam fluence profile, energy fluence profile, angular distribution, and spectral distribution. The results show that within PSF 1, the photon beam has an average scattering angle of 10.74° and a mean energy of 1.18 MeV. In PSF 2, the average scattering angle decreases to 2.63° while the mean energy increases to 1.50 MeV. The field size variation at 20×20, 30×30, and 40×40 cm2 affects both the angular and spectral distribution of the photon beam. The photon beam in PSF 2 exhibits an average scattering angle of 4.56, 6.31, and 6.66°, with corresponding mean energy values of 1.40, 1.32, and 1.30 MeV, respectively. These findings show that as the field size increases, the photon beam scatters at a larger angle while the energy decreases.

Authors

Institutions

Publication Details

Journal
International Journal of Advances in Applied Sciences
Published
2025-03-01
DOI
https://doi.org/10.11591/ijaas.v14.i1.pp227-234
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of 6 MV photon beam characteristics on Varian Clinac iX: a Monte Carlo study

Freddy Haryanto, Josua Timotius Manik, Anisza Okselia, Angelica Margaretha
International Journal of Advances in Applied Sciences
Advanced Radiotherapy Techniques
article

Evaluation of 6 MV photon beam characteristics on Varian Clinac iX: a Monte Carlo study

Freddy Haryanto, Josua Timotius Manik, Anisza Okselia, Angelica Margaretha
article en

Abstract

This work aims to study the characteristics of photon beams through phase space file (PSF) analysis using Monte Carlo (MC) simulation. 6 MV photon beams from the Varian Clinac iX were simulated using PRIMO software. The beam parameters were validated by evaluating the percentage depth dose and dose profile. A full PSF was scored at the downstream end of the linear accelerator (LINAC) upper and lower parts and analyzed to determine the beam fluence profile, energy fluence profile, angular distribution, and spectral distribution. The results show that within PSF 1, the photon beam has an average scattering angle of 10.74° and a mean energy of 1.18 MeV. In PSF 2, the average scattering angle decreases to 2.63° while the mean energy increases to 1.50 MeV. The field size variation at 20×20, 30×30, and 40×40 cm2 affects both the angular and spectral distribution of the photon beam. The photon beam in PSF 2 exhibits an average scattering angle of 4.56, 6.31, and 6.66°, with corresponding mean energy values of 1.40, 1.32, and 1.30 MeV, respectively. These findings show that as the field size increases, the photon beam scatters at a larger angle while the energy decreases.

International Journal of Advances in Applied SciencesVol. 14(1)
Bandung Institute of Technology (ID), Dr. Hasan Sadikin General Hospital (ID)
Openalex Percentile: Top 95%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.