Improvement of the optical cavity-based biosensor’s limit of detection using optimal 3-aminopropyltriethoxysilane process

Optical resonator-based biosensors are important for advancing medical diagnostics and environmental monitoring due to their high sensitivity and label-free detection capabilities. In this study, we present a systematic comparison of three 3-aminopropyltriethoxysilane (APTES) functionalization methods - ethanol-based, methanol-based, and vapor-phase - on an Optical Cavity-based Biosensor (OCB) designed to detect streptavidin. The APTES process is an important first step for surface functionalization to form a linker to immobilize receptor molecules on the sensor surface. Our aim was to identify the deposition conditions that yield a uniform APTES layer, with an enhanced bioreceptor immobilization and improved sensor performance. By using a differential detection approach using two laser diodes at 808 nm and 880 nm, we achieved real-time intensity measurements in the OCB that enabled sensitive detection of target analyte. Among the three APTES methods tested, the methanol-based protocol (0.095% APTES) led to a significantly improved limit of detection (LOD) of 27 ng/mL, a threefold improvement over our previous results. Detailed atomic force microscopy (AFM), contact angle, and dose-response analyses confirmed the high quality of the monolayer formed under optimal conditions, emphasizing the importance of solvent choice and controlled deposition parameters for obtaining stable functional layers. These findings emphasize how the improved APTES functionalization directly enhances the sensitivity and reliability of our OCB system, offering a robust and adaptable approach for real-time, label-free detection in diverse biosensing applications.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-05
DOI
https://doi.org/10.1038/s41598-025-92151-0
Citations
5
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
3.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement of the optical cavity-based biosensor’s limit of detection using optimal 3-aminopropyltriethoxysilane process

Aidan Hagemann, Marzhan Sypabekova, R. D. Wills, Bernd Zechmann et al.
5 citations
Scientific Reports
Photonic and Optical Devices
3.65
article

Improvement of the optical cavity-based biosensor’s limit of detection using optimal 3-aminopropyltriethoxysilane process

Aidan Hagemann, Marzhan Sypabekova, R. D. Wills, Bernd Zechmann, Jenna Kleiss, Seunghyun Kim, Sophia Schuemann
article en
5 citations

Abstract

Optical resonator-based biosensors are important for advancing medical diagnostics and environmental monitoring due to their high sensitivity and label-free detection capabilities. In this study, we present a systematic comparison of three 3-aminopropyltriethoxysilane (APTES) functionalization methods - ethanol-based, methanol-based, and vapor-phase - on an Optical Cavity-based Biosensor (OCB) designed to detect streptavidin. The APTES process is an important first step for surface functionalization to form a linker to immobilize receptor molecules on the sensor surface. Our aim was to identify the deposition conditions that yield a uniform APTES layer, with an enhanced bioreceptor immobilization and improved sensor performance. By using a differential detection approach using two laser diodes at 808 nm and 880 nm, we achieved real-time intensity measurements in the OCB that enabled sensitive detection of target analyte. Among the three APTES methods tested, the methanol-based protocol (0.095% APTES) led to a significantly improved limit of detection (LOD) of 27 ng/mL, a threefold improvement over our previous results. Detailed atomic force microscopy (AFM), contact angle, and dose-response analyses confirmed the high quality of the monolayer formed under optimal conditions, emphasizing the importance of solvent choice and controlled deposition parameters for obtaining stable functional layers. These findings emphasize how the improved APTES functionalization directly enhances the sensitivity and reliability of our OCB system, offering a robust and adaptable approach for real-time, label-free detection in diverse biosensing applications.

Scientific ReportsVol. 15(1)
Baylor University (US)
Openalex Percentile: Top 8%
Photonic and Optical Devices
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improvement of the optical cavity-based biosensor’s limit of detection using optimal 3-aminopropyltriethoxysilane process — Aidan Hagemann, Marzhan Sypabekova, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS