Prediction of Radiotherapy Dose Distribution for Glioblastoma Using Convolutional Neural Network Model
Aims: This study aims to predict radiotherapy dose distribution for glioblastoma patients using Machine Learning with a Convolutional Neural Network (CNN) model. Study Design: This research used an experimental design with a quantitative approach to predict radiotherapy dose distribution for glioblastoma patients using a CNN model. The study involved training and testing the CNN model on medical imaging data from The Cancer Imaging Archive (TCIA), evaluating its performance based on Mean Squared Error (MSE), Root Mean Squared Error (RMSE), Structural Similarity Index Measure (SSIM), Dice Similarity Coefficient (DSC), Peak Signal to Noise Ratio (PSNR), Normalized Cross-Correlation (NCC). The results were analyzed to determine the model’s accuracy in replicating actual dose distributions, providing a data-driven assessment of its predictive capability. Place and Duration of Study: This research was conducted in the Department of Physics at Udayana University from October 2024 to January 2025. Methodology: The research involved 180 patient datasets divided into 126 training data and 54 testing data. The CNN architecture is implemented using the Google Collaboratory platform. Model evaluation is performed using MSE, RMSE, and SSIM to measure the accuracy of dose distribution prediction. Results: The MSE, RMSE, SSIM, DSC, PSNR, and NCC values obtained from the CNN model are 0.00015795, 0.01256, 0.979718, 0.9711, 32dB, and 0.96289 respectively. The low MSE and RMSE values indicate minimal prediction error, while the high SSIM confirms strong structural similarity between the predicted and actual dose maps. The DSC demonstrates excellent spatial overlap, and the high PSNR reflects high-quality dose reconstruction. Additionally, the NCC highlights strong correlation with the ground truth. Visually, the axial, coronal, and sagittal slices closely resemble the actual dose distributions, further validating the model’s accuracy. Conclusion: The CNN model demonstrates effectiveness in predicting the dose distribution for glioblastoma radiotherapy, achieving highly accurate evaluation metrics. Visually, the model exhibit patterns highly similar to the actual dose map.
Authors
- Hery Suyanto (ORCID: https://orcid.org/0000-0002-0281-0424)
- Neha Rani (ORCID: https://orcid.org/0000-0003-1053-5714)
- I Gde Antha Kasmawan
- Anak Agung Ngurah Gunawan (ORCID: https://orcid.org/0000-0003-1886-7713)
- Gusti Ngurah Sutapa
- Ni Nyoman Ratini
Institutions
- Udayana University (ID)
Publication Details
- Journal
- Asian Journal of Medicine and Health
- Published
- 2025-03-05
- DOI
- https://doi.org/10.9734/ajmah/2025/v23i41198
- Primary Topic
- Brain Tumor Detection and Classification
- Type
- article
- Field-Weighted Citation Impact
- 0.00