The establishment of local diagnostic reference levels for computed tomography cerebral angiography in Jeddah city of Saudi Arabia

Abstract Purpose Cerebral computed tomography angiography (CTA) is a useful imaging modality for the diagnosis of blood vessels in brain diseases. The aim of this study was to assess the radiation dose and risk estimation for cerebral CTA scans for adult patients and introduce local diagnostic reference levels (LDRLs) for cerebral CTA patients. Methods In this retrospective study, 291 patients (194 male and 97 female) underwent cerebral CTA scans of the head. The dosimetric quantities of the CT dose index volume (CTDI vol ) and the dose length product (DLP) were collected. Following this, the effective dose, cancer risk and genetic risks were calculated. CTDI vol and DLP were derived; the suggested LDRLs were determined based on the 75th percentile for all examinations. Results The mean patient dose values for CTDI vol , DLP and effective dose were 42.83 ± 1.98 mGy, 1691.76 ± 128 mGy·cm and 5.20 ± 0.39 mSv, respectively. The CTDI vol value was the same for both sexes, while the DLP and effective dose values for males were 4% higher than for females. The cancer risk value for cerebral CTA was 29 × 10 −5 ± 3.2 Sv −1 , and the genetic risk was 10 × 10 −4 ± 1.2 Sv –1 . The LDRL value for CTDI vol was 32.36 (mGy) and for DLP was 1266.25 (mGy.cm). Conclusion This study assessed the radiation doses for cerebral CTA scans and introduced local DRLs for cerebral CTA examinations. In this study, the DLP and effective dose values were higher than those of other studies. The procedure of cerebral CTA scans that include total head and neck area should be optimized in regard to scan length and the head and neck k -factor. Therefore, it is highly recommended to establishing regional and national DRLs.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2025-03-05
DOI
https://doi.org/10.1186/s43055-025-01435-y
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The establishment of local diagnostic reference levels for computed tomography cerebral angiography in Jeddah city of Saudi Arabia

Saeed M. Al-Qahtani, Abdul-Wali Ajlouni, Ali Alomari, Merfat Algethami et al.
The Egyptian Journal of Radiology and Nuclear Medicine
Radiation Dose and Imaging
article

The establishment of local diagnostic reference levels for computed tomography cerebral angiography in Jeddah city of Saudi Arabia

Saeed M. Al-Qahtani, Abdul-Wali Ajlouni, Ali Alomari, Merfat Algethami, Abdulaziz H. Alharbi, Marwan Althomali, Omemh Bawazeer, K Khan, Mohamed Alasmary, Younis Bokhary, Emtenan Alotaibi, A Fallatah, Marwan Alhazmi
article en

Abstract

Abstract Purpose Cerebral computed tomography angiography (CTA) is a useful imaging modality for the diagnosis of blood vessels in brain diseases. The aim of this study was to assess the radiation dose and risk estimation for cerebral CTA scans for adult patients and introduce local diagnostic reference levels (LDRLs) for cerebral CTA patients. Methods In this retrospective study, 291 patients (194 male and 97 female) underwent cerebral CTA scans of the head. The dosimetric quantities of the CT dose index volume (CTDI vol ) and the dose length product (DLP) were collected. Following this, the effective dose, cancer risk and genetic risks were calculated. CTDI vol and DLP were derived; the suggested LDRLs were determined based on the 75th percentile for all examinations. Results The mean patient dose values for CTDI vol , DLP and effective dose were 42.83 ± 1.98 mGy, 1691.76 ± 128 mGy·cm and 5.20 ± 0.39 mSv, respectively. The CTDI vol value was the same for both sexes, while the DLP and effective dose values for males were 4% higher than for females. The cancer risk value for cerebral CTA was 29 × 10 −5 ± 3.2 Sv −1 , and the genetic risk was 10 × 10 −4 ± 1.2 Sv –1 . The LDRL value for CTDI vol was 32.36 (mGy) and for DLP was 1266.25 (mGy.cm). Conclusion This study assessed the radiation doses for cerebral CTA scans and introduced local DRLs for cerebral CTA examinations. In this study, the DLP and effective dose values were higher than those of other studies. The procedure of cerebral CTA scans that include total head and neck area should be optimized in regard to scan length and the head and neck k -factor. Therefore, it is highly recommended to establishing regional and national DRLs.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 56(1)
Alfaisal University (SA), Taif University (SA), Umm al-Qura University (SA), Maternity and Children's Hospital (SA), King Fahad Hospital Jeddah (SA)
Openalex Percentile: Top 94%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.