Concordance Between Estimated Fetal Weight by Ultrasound and Birth Weight and Its Association with Adverse Perinatal Outcomes

<b>Objective:</b> The aim of this study was to analyze the concordance between estimated fetal weight (EFW) and birth weight among ultrasound examinations with fetal biometry considered adequate and inadequate according to the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guidelines, and its association with adverse perinatal outcomes. <b>Methods:</b> This was a retrospective and cross-sectional study carried out in two centers, involving parturients who delivered between 37 and 41 weeks. The following parameters were evaluated: biparietal (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL) measurement; EFW; the interval between the ultrasound and delivery; and the discrepancy between EFW and birth weight. A minimum of 140 participants were required to assess the association between EFW and birth weight. <b>Results:</b> A total of 305 ultrasound examinations were selected and divided into two groups: adequate (Group I n = 115) and inadequate (Group II n = 190) fetal biometry. The measurements of the cephalic pole (BPD + HC), AC, and FL were inadequate in 69.5% (132/190), 91.6% (175/190), and 72.1% (137/190) of participants, respectively. Group I had a lower gestational age at ultrasound examination (38.4 vs. 39.9 weeks, <i>p</i> < 0.001), a larger BPD measurement (93.9 vs. 91.6 mm, <i>p</i> = 0.001), a longer interval between ultrasound examination and delivery (3.8 vs. 2.0 days, <i>p</i> < 0.001), and a smaller discrepancy between EFW and birth weight (7.2 vs. 9.5%, <i>p</i> = 0.002) than Group II. In Group I, EFW was a strong significant predictor (AUC:0.94, 95%CI 0.85-0.99, <i>p</i> = 0.032) for identifying birth weight >4000 g. An EFW cut-off value of 4019.0 g was found to be a correct identifier for 85.7% of newborns with a birth weight >4000 g, with a false-positive rate of 13.7%. Group I had a lower risk of postpartum hemorrhage (7.0% vs. 15.8%, OR:0.39, 95%CI 0.17-0.90, <i>p</i> = 0.024) and composite adverse perinatal outcomes (13.0 vs. 23.3%, OR:0.49, 95%CI 0.26-0.94, <i>p</i> = 0.030) than Group II. In Group I patients, undergoing an ultrasound 7 days before delivery was an independent predictor of composite adverse perinatal outcomes [x<sup>2</sup>(1) = 4.9, OR:0.49, 95%CI: 0.26-0.94, R<sup>2</sup> Nagelkerke:0.026, <i>p</i> = 0.030]. <b>Conclusions:</b> We observed a high rate of inadequate fetal biometry. There was poor concordance between EFW and birth weight. EFW was a strong significant predictor for identifying macrosomia. Ultrasound examination performed 7 days before delivery was an independent predictor of adverse perinatal outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-03-05
DOI
https://doi.org/10.3390/jcm14051757
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concordance Between Estimated Fetal Weight by Ultrasound and Birth Weight and Its Association with Adverse Perinatal Outcomes

Roberta Granese, Taciana Mara Rodrigues da Cunha Caldas, C Silva, Edward Araujo Júnior et al.
Journal of Clinical Medicine
Pregnancy and preeclampsia studies
article

Concordance Between Estimated Fetal Weight by Ultrasound and Birth Weight and Its Association with Adverse Perinatal Outcomes

Roberta Granese, Taciana Mara Rodrigues da Cunha Caldas, C Silva, Edward Araujo Júnior, Alberto Borges Peixoto, Artur Bizinotto
article en

Abstract

<b>Objective:</b> The aim of this study was to analyze the concordance between estimated fetal weight (EFW) and birth weight among ultrasound examinations with fetal biometry considered adequate and inadequate according to the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guidelines, and its association with adverse perinatal outcomes. <b>Methods:</b> This was a retrospective and cross-sectional study carried out in two centers, involving parturients who delivered between 37 and 41 weeks. The following parameters were evaluated: biparietal (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL) measurement; EFW; the interval between the ultrasound and delivery; and the discrepancy between EFW and birth weight. A minimum of 140 participants were required to assess the association between EFW and birth weight. <b>Results:</b> A total of 305 ultrasound examinations were selected and divided into two groups: adequate (Group I n = 115) and inadequate (Group II n = 190) fetal biometry. The measurements of the cephalic pole (BPD + HC), AC, and FL were inadequate in 69.5% (132/190), 91.6% (175/190), and 72.1% (137/190) of participants, respectively. Group I had a lower gestational age at ultrasound examination (38.4 vs. 39.9 weeks, <i>p</i> < 0.001), a larger BPD measurement (93.9 vs. 91.6 mm, <i>p</i> = 0.001), a longer interval between ultrasound examination and delivery (3.8 vs. 2.0 days, <i>p</i> < 0.001), and a smaller discrepancy between EFW and birth weight (7.2 vs. 9.5%, <i>p</i> = 0.002) than Group II. In Group I, EFW was a strong significant predictor (AUC:0.94, 95%CI 0.85-0.99, <i>p</i> = 0.032) for identifying birth weight >4000 g. An EFW cut-off value of 4019.0 g was found to be a correct identifier for 85.7% of newborns with a birth weight >4000 g, with a false-positive rate of 13.7%. Group I had a lower risk of postpartum hemorrhage (7.0% vs. 15.8%, OR:0.39, 95%CI 0.17-0.90, <i>p</i> = 0.024) and composite adverse perinatal outcomes (13.0 vs. 23.3%, OR:0.49, 95%CI 0.26-0.94, <i>p</i> = 0.030) than Group II. In Group I patients, undergoing an ultrasound 7 days before delivery was an independent predictor of composite adverse perinatal outcomes [x<sup>2</sup>(1) = 4.9, OR:0.49, 95%CI: 0.26-0.94, R<sup>2</sup> Nagelkerke:0.026, <i>p</i> = 0.030]. <b>Conclusions:</b> We observed a high rate of inadequate fetal biometry. There was poor concordance between EFW and birth weight. EFW was a strong significant predictor for identifying macrosomia. Ultrasound examination performed 7 days before delivery was an independent predictor of adverse perinatal outcomes.

Journal of Clinical MedicineVol. 14(5)
Universidade Municipal de São Caetano do Sul (BR), Sabin Medicina Diagnostica (Brazil) (BR), Universidade Federal do Triângulo Mineiro (BR), Universidade de Uberaba (BR), Universidade Federal de São Paulo (BR)
Openalex Percentile: Top 94%
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.