Third Body Wear of an All-Polymer, PEEK-OPTIMA™ on Ultra-High-Molecular-Weight Polyethylene Total Knee Replacement

Experimental wear simulation of a PEEK-OPTIMA™ polymer-on-UHMWPE total knee replacement has shown equivalent UHMWPE wear to conventional knee replacement materials (cobalt chrome-on-UHMWPE) when tested in a clean environment. The aim of this study was to experimentally investigate the wear of this all-polymer total knee replacement under third body wear conditions. Three PEEK-OPTIMA™ and three cobalt chrome femoral components articulating against all-polyethylene tibial components were tested in a knee simulator. One million cycles of wear simulation was carried out in clean lubricant under conditions replicating walking followed by one million cycles with the lubricant contaminated with porcine bone particles, then one million cycles with PMMA cement particles. UHMWPE wear was determined gravimetrically. Statistical analysis compared UHMWPE wear against PEEK femoral components to cobalt chrome. In clean lubricant and with bone particles in the lubricant, there was no significant difference (<i>p</i> > 0.05) in UHMWPE wear against the different femoral component materials, and wear rates were similar under both conditions. With PMMA particles, there was a dramatic increase in UHMWPE wear for both knee replacement systems but no significant difference (<i>p</i> > 0.05) in UHMWPE wear between the femoral component materials. This is the first study to investigate wear of an all-polymer knee under third body wear conditions.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-03-05
DOI
https://doi.org/10.3390/bioengineering12030261
Citations
3
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
6.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Third Body Wear of an All-Polymer, PEEK-OPTIMA™ on Ultra-High-Molecular-Weight Polyethylene Total Knee Replacement

Louise M. Jennings, Thomas M. Grupp, Jens Schwiesau, Adam Briscoe et al.
3 citations
Bioengineering
Orthopaedic implants and arthroplasty
6.02
article

Third Body Wear of an All-Polymer, PEEK-OPTIMA™ on Ultra-High-Molecular-Weight Polyethylene Total Knee Replacement

Louise M. Jennings, Thomas M. Grupp, Jens Schwiesau, Adam Briscoe, Raelene M. Cowie
article en
3 citations

Abstract

Experimental wear simulation of a PEEK-OPTIMA™ polymer-on-UHMWPE total knee replacement has shown equivalent UHMWPE wear to conventional knee replacement materials (cobalt chrome-on-UHMWPE) when tested in a clean environment. The aim of this study was to experimentally investigate the wear of this all-polymer total knee replacement under third body wear conditions. Three PEEK-OPTIMA™ and three cobalt chrome femoral components articulating against all-polyethylene tibial components were tested in a knee simulator. One million cycles of wear simulation was carried out in clean lubricant under conditions replicating walking followed by one million cycles with the lubricant contaminated with porcine bone particles, then one million cycles with PMMA cement particles. UHMWPE wear was determined gravimetrically. Statistical analysis compared UHMWPE wear against PEEK femoral components to cobalt chrome. In clean lubricant and with bone particles in the lubricant, there was no significant difference (<i>p</i> > 0.05) in UHMWPE wear against the different femoral component materials, and wear rates were similar under both conditions. With PMMA particles, there was a dramatic increase in UHMWPE wear for both knee replacement systems but no significant difference (<i>p</i> > 0.05) in UHMWPE wear between the femoral component materials. This is the first study to investigate wear of an all-polymer knee under third body wear conditions.

BioengineeringVol. 12(3)
University of Leeds (GB), Materials Solutions (United Kingdom) (GB), Ludwig-Maximilians-Universität München (DE)
Engineering and Physical Sciences Research Council
Openalex Percentile: Top 5%
Orthopaedic implants and arthroplasty
6.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.