Flame Spread on an Active Photovoltaic–Roof System

Solar photovoltaic (PV) systems in buildings must comply with both electrotechnical standards for module safety and local building codes, which typically do not address their electrical nature. This regulatory gap creates challenges in assessing the fire performance of PV systems. This paper presents a procedure to adapt a common test method used in some building codes to assess external fire conditions for roofs, while maintaining operative PV modules. Two configurations were tested: an organic PV thin film on a metallic sandwich panel and a glass–glass-encapsulated organic PV module. The tests were conducted under high voltage and current conditions to simulate the systems’ behavior within a larger PV array. Significant electric arcs were observed during testing of the metallic sandwich panel configuration without glass protection when subjected to high voltages or currents. In these cases, total heat release increased by at least 30% compared to non-electrically loaded scenarios or glass-insulated PV modules, likely due to a greater damaged surface area. Electric arcs created new ignition sources, damaging whole PV modules, whereas in the case with no electrical load, propagation flames advanced toward both the upper edge and the corners of the sample, ultimately damaging the entire triangular area above the fire source. The results indicate that the electrical characteristics of PV systems can significantly impact external fire spread behavior. The study identifies challenges in maintaining system activity during testing and simulating real scenarios and proposes for future research directions.

Authors

Institutions

Publication Details

Journal
Fire
Published
2025-03-05
DOI
https://doi.org/10.3390/fire8030105
Citations
2
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flame Spread on an Active Photovoltaic–Roof System

Iñigo Vidaurrazaga, Xabat Oregi, Xabier Olano‐Azkune, Daniel Valencia-Caballero et al.
2 citations
Fire
Photovoltaic System Optimization Techniques
0.73
article

Flame Spread on an Active Photovoltaic–Roof System

Iñigo Vidaurrazaga, Xabat Oregi, Xabier Olano‐Azkune, Daniel Valencia-Caballero, Olaia Aurrekoetxea‐Arratibel, Nerea Otano-Aramendi
article en
2 citations

Abstract

Solar photovoltaic (PV) systems in buildings must comply with both electrotechnical standards for module safety and local building codes, which typically do not address their electrical nature. This regulatory gap creates challenges in assessing the fire performance of PV systems. This paper presents a procedure to adapt a common test method used in some building codes to assess external fire conditions for roofs, while maintaining operative PV modules. Two configurations were tested: an organic PV thin film on a metallic sandwich panel and a glass–glass-encapsulated organic PV module. The tests were conducted under high voltage and current conditions to simulate the systems’ behavior within a larger PV array. Significant electric arcs were observed during testing of the metallic sandwich panel configuration without glass protection when subjected to high voltages or currents. In these cases, total heat release increased by at least 30% compared to non-electrically loaded scenarios or glass-insulated PV modules, likely due to a greater damaged surface area. Electric arcs created new ignition sources, damaging whole PV modules, whereas in the case with no electrical load, propagation flames advanced toward both the upper edge and the corners of the sample, ultimately damaging the entire triangular area above the fire source. The results indicate that the electrical characteristics of PV systems can significantly impact external fire spread behavior. The study identifies challenges in maintaining system activity during testing and simulating real scenarios and proposes for future research directions.

FireVol. 8(3)
University of the Basque Country (ES), Tecnalia (ES)
European Commission
Openalex Percentile: Top 33%
Photovoltaic System Optimization Techniques
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.