Training Intensity Needed for Volume Linearity and Syringe D <sub>LCO</sub> Check Quality Control

<b>Background:</b> Technologists must assure the accuracy and precision of pulmonary function equipment prior to testing patients. This study aimed to identify the sources of failure and unacceptable submission rates for spirometry volume linearity and syringe diffusing capacity of the lung for carbon monoxide (D<sub>LCO</sub>) check quality control (QC). In addition, we explored whether the time between training and first QC submission affected overall percentage of unacceptable submissions. <b>Methods:</b> Participants in a cross-sectional global study submitted QC for evaluation from October 2014 to May 2018 from 114 laboratories. Descriptive statistics summarized the percentage of unacceptable submissions and sources of failure for volume linearity and syringe D<sub>LCO</sub> check maneuvers. Spearman's rho described the correlation between site-specific unacceptable submission rates, and both days between training and the first unacceptable submission and the days between training and first submission. <b>Results:</b> The unacceptable submission rate from 5,083 volume linearity assessments was 10% compared with a 6.2% rate from 4,992 syringe D<sub>LCO</sub> check maneuvers. Aggregate volume linearity rates of procedural errors (5.8%) and equipment errors (6.2%) were similar, whereas there were more syringe D<sub>LCO</sub> check equipment errors (5.9%) than procedural errors (0.78%). The time between training and submitting a QC test was not related to overall unacceptable submission rates for volume linearity and syringe D<sub>LCO</sub> check, <i>r<sub>sp</sub></i> = 0.11, <i>P</i> = .27 and <i>r<sub>sp</sub></i> = 0.19, <i>P</i> = .052, respectively. Higher unacceptable rates occurred when the first QC failure occurred close to the completion of training for volume linearity and syringe D<sub>LCO</sub> check, <i>r<sub>sp</sub></i> = -0.41, <i>P</i> < .001 and <i>r<sub>sp</sub></i> = -0.38, <i>P</i> < .001, respectively. <b>Conclusions:</b> A single QC training session does not adequately prepare technologists to conduct QC. Technologists need clear and consistent guidelines for conducting QC procedures and regular follow-up from experts to properly interpret QC findings, resolve equipment problems, and assure their testing systems are in-control.

Authors

Institutions

Publication Details

Journal
Respiratory Care
Published
2025-03-07
DOI
https://doi.org/10.1089/respcare.12565
Citations
1
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Training Intensity Needed for Volume Linearity and Syringe D LCO Check Quality Control

Ellen A Becker, E Morán, V. Rodríguez, Susan Blonshine et al.
1 citations
Respiratory Care
Chronic Obstructive Pulmonary Disease (COPD) Research
1.52
article

Training Intensity Needed for Volume Linearity and Syringe D LCO Check Quality Control

Ellen A Becker, E Morán, V. Rodríguez, Susan Blonshine, Jason Blonshine
article en
1 citations

Abstract

<b>Background:</b> Technologists must assure the accuracy and precision of pulmonary function equipment prior to testing patients. This study aimed to identify the sources of failure and unacceptable submission rates for spirometry volume linearity and syringe diffusing capacity of the lung for carbon monoxide (D<sub>LCO</sub>) check quality control (QC). In addition, we explored whether the time between training and first QC submission affected overall percentage of unacceptable submissions. <b>Methods:</b> Participants in a cross-sectional global study submitted QC for evaluation from October 2014 to May 2018 from 114 laboratories. Descriptive statistics summarized the percentage of unacceptable submissions and sources of failure for volume linearity and syringe D<sub>LCO</sub> check maneuvers. Spearman's rho described the correlation between site-specific unacceptable submission rates, and both days between training and the first unacceptable submission and the days between training and first submission. <b>Results:</b> The unacceptable submission rate from 5,083 volume linearity assessments was 10% compared with a 6.2% rate from 4,992 syringe D<sub>LCO</sub> check maneuvers. Aggregate volume linearity rates of procedural errors (5.8%) and equipment errors (6.2%) were similar, whereas there were more syringe D<sub>LCO</sub> check equipment errors (5.9%) than procedural errors (0.78%). The time between training and submitting a QC test was not related to overall unacceptable submission rates for volume linearity and syringe D<sub>LCO</sub> check, <i>r<sub>sp</sub></i> = 0.11, <i>P</i> = .27 and <i>r<sub>sp</sub></i> = 0.19, <i>P</i> = .052, respectively. Higher unacceptable rates occurred when the first QC failure occurred close to the completion of training for volume linearity and syringe D<sub>LCO</sub> check, <i>r<sub>sp</sub></i> = -0.41, <i>P</i> < .001 and <i>r<sub>sp</sub></i> = -0.38, <i>P</i> < .001, respectively. <b>Conclusions:</b> A single QC training session does not adequately prepare technologists to conduct QC. Technologists need clear and consistent guidelines for conducting QC procedures and regular follow-up from experts to properly interpret QC findings, resolve equipment problems, and assure their testing systems are in-control.

Respiratory CareVol. 70(8)
Rush University Medical Center (US), Medical Physics Consultants (US), International Consultants (Egypt) (EG)
Climate action
Openalex Percentile: Top 21%
Chronic Obstructive Pulmonary Disease (COPD) Research
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.