Optimal Parameters and Placement of Hybrid Energy Storage Systems for Frequency Stability Improvement

Energy storage with virtual inertia and virtual droop control has attracted wide attention due to its improved frequency stability with high penetration of renewable energy sources. However, there are significant spatial differences in frequency response. The location and capacity of energy storage are urgent issues to be resolved to support frequency. This study addresses the minimum investment of hybrid energy storage systems for providing sufficient frequency support, including the power capacity, energy capacity, and location of energy storage. A frequency response model is developed taking into account the network structure and frequency spatial distribution characteristics. In addition, a numerical computation method is provided for determining the frequency dynamic indices and calculating the output power of energy storage. Based on a simplified frequency response model, an optimal hybrid energy storage configuration method is proposed to optimize the control parameters, location, and capacity to satisfy the frequency dynamic constraints. This configuration method can exploit the potential of energy storage with different rates in different frequency support stages. To address the nonconvex drawback of this configuration, a numerical calculation method is provided based on the explicit gradient of the frequency and energy storage indices to enhance the computational efficiency. Simulations of a two-area system and the south-east Australian system verify the effectiveness of the proposed hybrid energy storage configuration method.

Authors

Institutions

Publication Details

Journal
Protection and Control of Modern Power Systems
Published
2025-03-01
DOI
https://doi.org/10.23919/pcmp.2023.000259
Citations
20
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
24.29

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Parameters and Placement of Hybrid Energy Storage Systems for Frequency Stability Improvement

Dan Liu, Qiufan Yang, Xia Chen, Yin Chen et al.
20 citations
Protection and Control of Modern Power Systems
Microgrid Control and Optimization
24.29
article

Optimal Parameters and Placement of Hybrid Energy Storage Systems for Frequency Stability Improvement

Dan Liu, Qiufan Yang, Xia Chen, Yin Chen, Jinyu Wen
article en
20 citations

Abstract

Energy storage with virtual inertia and virtual droop control has attracted wide attention due to its improved frequency stability with high penetration of renewable energy sources. However, there are significant spatial differences in frequency response. The location and capacity of energy storage are urgent issues to be resolved to support frequency. This study addresses the minimum investment of hybrid energy storage systems for providing sufficient frequency support, including the power capacity, energy capacity, and location of energy storage. A frequency response model is developed taking into account the network structure and frequency spatial distribution characteristics. In addition, a numerical computation method is provided for determining the frequency dynamic indices and calculating the output power of energy storage. Based on a simplified frequency response model, an optimal hybrid energy storage configuration method is proposed to optimize the control parameters, location, and capacity to satisfy the frequency dynamic constraints. This configuration method can exploit the potential of energy storage with different rates in different frequency support stages. To address the nonconvex drawback of this configuration, a numerical calculation method is provided based on the explicit gradient of the frequency and energy storage indices to enhance the computational efficiency. Simulations of a two-area system and the south-east Australian system verify the effectiveness of the proposed hybrid energy storage configuration method.

Protection and Control of Modern Power SystemsVol. 10(2)
University of Strathclyde (GB), Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 0%
Microgrid Control and Optimization
24.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.