Wearable devices for arrhythmia diagnosis are battery-powered and require improved power efficiency. In our previous study, we applied approximate computing, which is effective for power reduction, to QRS identification algorithm and achieved significant power reduction. However, the impact of this approximation on arrhythmia detection and classification was not fully investigated. In this study, we investigate how the approximation --- specifically, the use of two approximate multipliers and eight approximate squarers applied to the Pan-Tompkins algorithm --- affects RR interval-based arrhythmia detection and classification. We use 48 samples from the MIT-BIH Arrhythmia Database to evaluate the accuracy of arrhythmia detection and classification. It was found that the approximate multiplier mul16s_GQU is the best choice, achieving nearly 100<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">%</sup> accuracy and less than 1 % false negatives in abnormal/normal classification. Additionally, the most power-efficient approximate squarer, E10C1, achieves relatively high accuracy with less than 5 % false negatives.

Authors

Institutions

Publication Details

Published
2024-10-26
DOI
https://doi.org/10.1109/cisp-bmei64163.2024.10906078
Citations
4
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
1.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Approximate QRS Identification on RR Interval-Based Arrhythmia Detection and Classification

T. Nagatomo, Toshinori Sato
4 citations
ECG Monitoring and Analysis
1.61
article

Impact of Approximate QRS Identification on RR Interval-Based Arrhythmia Detection and Classification

T. Nagatomo, Toshinori Sato
article en
4 citations

Abstract

Wearable devices for arrhythmia diagnosis are battery-powered and require improved power efficiency. In our previous study, we applied approximate computing, which is effective for power reduction, to QRS identification algorithm and achieved significant power reduction. However, the impact of this approximation on arrhythmia detection and classification was not fully investigated. In this study, we investigate how the approximation --- specifically, the use of two approximate multipliers and eight approximate squarers applied to the Pan-Tompkins algorithm --- affects RR interval-based arrhythmia detection and classification. We use 48 samples from the MIT-BIH Arrhythmia Database to evaluate the accuracy of arrhythmia detection and classification. It was found that the approximate multiplier mul16s_GQU is the best choice, achieving nearly 100<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">%</sup> accuracy and less than 1 % false negatives in abnormal/normal classification. Additionally, the most power-efficient approximate squarer, E10C1, achieves relatively high accuracy with less than 5 % false negatives.

Fukuoka University (JP)
Openalex Percentile: Top 14%
ECG Monitoring and Analysis
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Approximate QRS Identification on RR Interval-Based Arrhythmia Detection and Classification — T. Nagatomo, Toshinori Sato · (2024) | TGRS Research Map | TGRS