CBCTformer: Transformer Model for Sparse-View CBCT Artifact Reduction in Image-Guided Radiotherapy

This study proposes a Transformer-based image domain model, named CBCTformer, for artifact reduction in sparse-view cone-beam computed tomography (CBCT) used in image-guided radiotherapy (IGRT). The CBCTformer model is built on a Swin Transformer U-Net architecture, comprising both encoder and decoder components. The model was trained, validated, and tested on CBCT data from 163, 30, and 30 real patients, respectively. Quantitative metrics including root-mean-square error (RMSE), peak signal-to-noise ratio (PSNR), structural similarity (SSIM), and feature similarity (FSIM) were used to evaluate the model's performance. The CBCTformer model was compared with four state-of-art (SOTA) convolutional neural network (CNN)-based models on the 1/8 sparse-view reconstruction task. On the test set, the CBCTformer model achieved averaged RMSE, PSNR, SSIM and FSIM values of 0.001098, 35.67 dB, 0.8714 and 0.97, respectively, outperforming all the four SOTA CNN models across all metrics. In conclusion, the proposed CBCTformer model effectively reduces artifacts in sparse-view CBCT images, thereby improving CBCT image quality in IGRT.

Authors

Institutions

Publication Details

Published
2024-10-26
DOI
https://doi.org/10.1109/cisp-bmei64163.2024.10906196
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CBCTformer: Transformer Model for Sparse-View CBCT Artifact Reduction in Image-Guided Radiotherapy

Yi Du, Jupeng Li, Lei Sui, Xuzhi Zhao et al.
1 citations
Medical Imaging Techniques and Applications
0.40
article

CBCTformer: Transformer Model for Sparse-View CBCT Artifact Reduction in Image-Guided Radiotherapy

Yi Du, Jupeng Li, Lei Sui, Xuzhi Zhao, Yahui Peng, Keming Chen
article en
1 citations

Abstract

This study proposes a Transformer-based image domain model, named CBCTformer, for artifact reduction in sparse-view cone-beam computed tomography (CBCT) used in image-guided radiotherapy (IGRT). The CBCTformer model is built on a Swin Transformer U-Net architecture, comprising both encoder and decoder components. The model was trained, validated, and tested on CBCT data from 163, 30, and 30 real patients, respectively. Quantitative metrics including root-mean-square error (RMSE), peak signal-to-noise ratio (PSNR), structural similarity (SSIM), and feature similarity (FSIM) were used to evaluate the model's performance. The CBCTformer model was compared with four state-of-art (SOTA) convolutional neural network (CNN)-based models on the 1/8 sparse-view reconstruction task. On the test set, the CBCTformer model achieved averaged RMSE, PSNR, SSIM and FSIM values of 0.001098, 35.67 dB, 0.8714 and 0.97, respectively, outperforming all the four SOTA CNN models across all metrics. In conclusion, the proposed CBCTformer model effectively reduces artifacts in sparse-view CBCT images, thereby improving CBCT image quality in IGRT.

Peking University (CN), Beijing Jiaotong University (CN), Peking University Cancer Hospital (CN)
National Natural Science Foundation of China, Natural Science Foundation of Beijing Municipality
Openalex Percentile: Top 31%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.