Optimized Evaluation Methods and Automatic Calibration Equipment for Primary Display

In order to improve existing calibration approaches for the core parameters of primary display, optimized evaluation methods as well as automatic calibration equipment were proposed in this paper. Uniformly spaced sampling method was adopted to get more accurate and reliable results for luminance uniformity and display chromaticity measurement. And luminance distribution of primary display was intuitively presented in the form of contour map to present the luminance uniformity more visually. To realize the detection of viewing angle, a quantitative method was also implemented through the cooperation of software and hardware. Therefore, the equipment could obviously achieve automatic calibration with high efficiency. Experimental results from 4 different primary displays showed clear differences between nominal and measured values of their core parameters, which indicated the necessity to perform regular calibration on primary display. The main components of the calibration equipment could be traced to Chinese National Primary Standards, thereby ensuring accuracy and reliability of measurement results.

Authors

Institutions

Publication Details

Published
2024-10-26
DOI
https://doi.org/10.1109/cisp-bmei64163.2024.10906161
Primary Topic
Manufacturing Process and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized Evaluation Methods and Automatic Calibration Equipment for Primary Display

Zhengshan Huang, Jie Sun, Peng Zhang, Chengwei Li et al.
Manufacturing Process and Optimization
article

Optimized Evaluation Methods and Automatic Calibration Equipment for Primary Display

Zhengshan Huang, Jie Sun, Peng Zhang, Chengwei Li, Jiao Li, Pu Zhang
article en

Abstract

In order to improve existing calibration approaches for the core parameters of primary display, optimized evaluation methods as well as automatic calibration equipment were proposed in this paper. Uniformly spaced sampling method was adopted to get more accurate and reliable results for luminance uniformity and display chromaticity measurement. And luminance distribution of primary display was intuitively presented in the form of contour map to present the luminance uniformity more visually. To realize the detection of viewing angle, a quantitative method was also implemented through the cooperation of software and hardware. Therefore, the equipment could obviously achieve automatic calibration with high efficiency. Experimental results from 4 different primary displays showed clear differences between nominal and measured values of their core parameters, which indicated the necessity to perform regular calibration on primary display. The main components of the calibration equipment could be traced to Chinese National Primary Standards, thereby ensuring accuracy and reliability of measurement results.

National Institute of Metrology (CN)
Affordable and clean energy
Openalex Percentile: Top 59%
Manufacturing Process and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimized Evaluation Methods and Automatic Calibration Equipment for Primary Display — Zhengshan Huang, Jie Sun, et al. · (2024) | TGRS Research Map | TGRS