Research on Heart Rate Signal Detection Technology Based on Hough Transform

Radar-based vital sign detection technology, especially for heart rate detection, has a wide range of application prospects in the fields such as medical monitoring, disaster rescue. A novel signal processing scheme is proposed for accurate heart rate detection in this paper. Initially, during the preprocessing phase, the phase ambiguity issue resulting from directly applying the inverse tangent function is addressed using the extended differential and cross-multiplication (DACM) algorithm. Secondly, a novel method for identifying and suppressing respiration harmonics, referred to as IHT, is proposed. This method is based on Hough transformation, parallel and serial searching methods, and the Chirp-Z Transform (CZT), which improves the accuracy of heart rate estimation and reduces computation time. On this basis, Kalman filtering (KF) is utilized for smoothing and denoising. Finally, the CZT high-precision frequency estimation algorithm is used for spectrum analysis and heart rate estimation. Extensive experiments demonstrate that the mean absolute error (Mae) of the proposed method is 0.95bpm, which is 1.23bpm better than the original Hough transform method.

Authors

Institutions

Publication Details

Published
2024-10-26
DOI
https://doi.org/10.1109/cisp-bmei64163.2024.10906262
Primary Topic
Traditional Chinese Medicine Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Heart Rate Signal Detection Technology Based on Hough Transform

Jiewen Xiao, Qitong Li, Yuqing Song, Yunxue Liu et al.
Traditional Chinese Medicine Studies
article

Research on Heart Rate Signal Detection Technology Based on Hough Transform

Jiewen Xiao, Qitong Li, Yuqing Song, Yunxue Liu, Xiaolin Xu, Yousheng Wang
article en

Abstract

Radar-based vital sign detection technology, especially for heart rate detection, has a wide range of application prospects in the fields such as medical monitoring, disaster rescue. A novel signal processing scheme is proposed for accurate heart rate detection in this paper. Initially, during the preprocessing phase, the phase ambiguity issue resulting from directly applying the inverse tangent function is addressed using the extended differential and cross-multiplication (DACM) algorithm. Secondly, a novel method for identifying and suppressing respiration harmonics, referred to as IHT, is proposed. This method is based on Hough transformation, parallel and serial searching methods, and the Chirp-Z Transform (CZT), which improves the accuracy of heart rate estimation and reduces computation time. On this basis, Kalman filtering (KF) is utilized for smoothing and denoising. Finally, the CZT high-precision frequency estimation algorithm is used for spectrum analysis and heart rate estimation. Extensive experiments demonstrate that the mean absolute error (Mae) of the proposed method is 0.95bpm, which is 1.23bpm better than the original Hough transform method.

Yantai University (CN)
Openalex Percentile: Top 50%
Traditional Chinese Medicine Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Heart Rate Signal Detection Technology Based on Hough Transform — Jiewen Xiao, Qitong Li, et al. · (2024) | TGRS Research Map | TGRS