A Dual-path Interactive ECG Denoising Algorithm

Denoising of dynamic electrocardiography (ECG) is a hotspot in ECG processing. Existing denoising methods mainly target single-lead signals or single noise sources, with limited research addressing mixed noise across multiple leads. To address the aforementioned issues, this study proposes a Dual-Path Interactive Denoising Autoencoder (DP-IDAE). The Convolutional Local Denoising Path (CL-Path) of DP-IDAE employs convolutional operations to extract local features of the ECG signal, while the Temporal Global Denoising Path (TG-Path) utilizes bidirectional Long Short-Term Memory networks to capture the signal's temporal global features. Additionally, an Interactive Communication Mechanism (ICM) based on the attention mechanism is proposed to facilitate the exchange of information between the different features of the two paths. The model was tested on denoising performance under different input signal-to-noise ratios for seven types of noise, including single and mixed noise sources comprising baseline wander (BW), muscle artifact (MA), and electrode motion (EM), which are common noise sources in ECG signals. In the MIT-BIH Arrhythmia Database (MLII lead), experimental results demonstrate the superiority of DP-IDAE in ECG signal denoising. Additionally, the study investigates the relationship between denoising effects and signal similarity of different lead ECG, demonstrating excellent cross-lead generalization performance.

Authors

Institutions

Publication Details

Published
2024-10-26
DOI
https://doi.org/10.1109/cisp-bmei64163.2024.10906137
Citations
1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Dual-path Interactive ECG Denoising Algorithm

Xiuxin Zhang, Jiahui Gao, Shoushui Wei, Meng Chen et al.
1 citations
ECG Monitoring and Analysis
0.40
article

A Dual-path Interactive ECG Denoising Algorithm

Xiuxin Zhang, Jiahui Gao, Shoushui Wei, Meng Chen, Feifei Liu, Yongjian Li, Yiheng Sun
article en
1 citations

Abstract

Denoising of dynamic electrocardiography (ECG) is a hotspot in ECG processing. Existing denoising methods mainly target single-lead signals or single noise sources, with limited research addressing mixed noise across multiple leads. To address the aforementioned issues, this study proposes a Dual-Path Interactive Denoising Autoencoder (DP-IDAE). The Convolutional Local Denoising Path (CL-Path) of DP-IDAE employs convolutional operations to extract local features of the ECG signal, while the Temporal Global Denoising Path (TG-Path) utilizes bidirectional Long Short-Term Memory networks to capture the signal's temporal global features. Additionally, an Interactive Communication Mechanism (ICM) based on the attention mechanism is proposed to facilitate the exchange of information between the different features of the two paths. The model was tested on denoising performance under different input signal-to-noise ratios for seven types of noise, including single and mixed noise sources comprising baseline wander (BW), muscle artifact (MA), and electrode motion (EM), which are common noise sources in ECG signals. In the MIT-BIH Arrhythmia Database (MLII lead), experimental results demonstrate the superiority of DP-IDAE in ECG signal denoising. Additionally, the study investigates the relationship between denoising effects and signal similarity of different lead ECG, demonstrating excellent cross-lead generalization performance.

Shandong University (CN), Shandong Jianzhu University (CN)
Openalex Percentile: Top 29%
ECG Monitoring and Analysis
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Dual-path Interactive ECG Denoising Algorithm — Xiuxin Zhang, Jiahui Gao, et al. · (2024) | TGRS Research Map | TGRS