A Predictive Marker for Right Heart Failure After Left Ventricular Assist Device Implantation: The Direct Bilirubin to Total Bilirubin Ratio

Early right heart failure (RHF) after left ventricular assist device (LVAD) implantation poses significant morbidity and mortality risks. Existing RHF prediction scores are complex, typically requiring multiple indicators and evaluation steps. This research aimed to explore a more feasible predictor for initial screening of early RHF. This multicenter, retrospective analysis included 83 consecutively enrolled patients undergoing continuous-flow LVAD implantation. Multivariable logistic regression identified independent predictors of early RHF, whereas receiver operating characteristic (ROC) curve analysis assessed predictive value. Among the 83 patients, 21 (25.3%) experienced early RHF. Logistic regression analyses revealed that the direct bilirubin to total bilirubin (DBIL/TBIL) ratio on admission was significantly correlated with early RHF (adjusted odds ratio [OR]: 2.41, 95% confidence interval [CI]: 1.35-4.31, p = 0.003). The DBIL/TBIL ratio on admission exhibited the highest area under the receiver operating characteristic curve (AUC) (0.767, 95% CI: 0.661-0.852). Internal validation using bootstrap techniques resulted in a mean AUC of 0.767 (95% CI: 0.640-0.879), whereas external validation in a cohort of 31 patients demonstrated an AUC of 0.682 (95% CI: 0.491-0.837). An optimal DBIL/TBIL ratio threshold of 0.52 yielded 76.19% sensitivity and 79.03% specificity for early RHF prediction. In subgroups with different TBIL levels, sensitivity and specificity were 70.0% and 86.67% for TBIL greater than or equal to 2 mg/dl, and 81.82% and 76.60% for TBIL less than 2 mg/dl, respectively. The DBIL/TBIL ratio upon admission is a viable predictor of early RHF following LVAD implantation, demonstrating acceptable predictive efficacy.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2025-03-06
DOI
https://doi.org/10.1097/mat.0000000000002398
Citations
3
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Predictive Marker for Right Heart Failure After Left Ventricular Assist Device Implantation: The Direct Bilirubin to Total Bilirubin Ratio

Liang Zou, Xian-Qiang Wang, Xingtong Zhou, Haibo Chen et al.
3 citations
ASAIO Journal
Mechanical Circulatory Support Devices
2.02
article

A Predictive Marker for Right Heart Failure After Left Ventricular Assist Device Implantation: The Direct Bilirubin to Total Bilirubin Ratio

Liang Zou, Xian-Qiang Wang, Xingtong Zhou, Haibo Chen, Shengshou Hu, Ping Qing, Juan Du, Sheng Zhao, Fujian Duan
article en
3 citations

Abstract

Early right heart failure (RHF) after left ventricular assist device (LVAD) implantation poses significant morbidity and mortality risks. Existing RHF prediction scores are complex, typically requiring multiple indicators and evaluation steps. This research aimed to explore a more feasible predictor for initial screening of early RHF. This multicenter, retrospective analysis included 83 consecutively enrolled patients undergoing continuous-flow LVAD implantation. Multivariable logistic regression identified independent predictors of early RHF, whereas receiver operating characteristic (ROC) curve analysis assessed predictive value. Among the 83 patients, 21 (25.3%) experienced early RHF. Logistic regression analyses revealed that the direct bilirubin to total bilirubin (DBIL/TBIL) ratio on admission was significantly correlated with early RHF (adjusted odds ratio [OR]: 2.41, 95% confidence interval [CI]: 1.35-4.31, p = 0.003). The DBIL/TBIL ratio on admission exhibited the highest area under the receiver operating characteristic curve (AUC) (0.767, 95% CI: 0.661-0.852). Internal validation using bootstrap techniques resulted in a mean AUC of 0.767 (95% CI: 0.640-0.879), whereas external validation in a cohort of 31 patients demonstrated an AUC of 0.682 (95% CI: 0.491-0.837). An optimal DBIL/TBIL ratio threshold of 0.52 yielded 76.19% sensitivity and 79.03% specificity for early RHF prediction. In subgroups with different TBIL levels, sensitivity and specificity were 70.0% and 86.67% for TBIL greater than or equal to 2 mg/dl, and 81.82% and 76.60% for TBIL less than 2 mg/dl, respectively. The DBIL/TBIL ratio upon admission is a viable predictor of early RHF following LVAD implantation, demonstrating acceptable predictive efficacy.

ASAIO JournalVol. 71(6)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
National Key Research and Development Program of China
Good health and well-being
Openalex Percentile: Top 15%
Mechanical Circulatory Support Devices
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.