Energy filtering enables macromolecular MicroED data at sub-atomic resolution

High-resolution information is important for accurate structure modeling but is challenging to attain in macromolecular crystallography due to the rapid fading of diffracted intensities at increasing resolution. While direct electron detection essentially eliminates the read-out noise during MicroED data collection, other sources of noise remain and limit the measurement of faint high-resolution reflections. Inelastic scattering significantly contributes to noise, raising background levels and broadening diffraction peaks. We demonstrate a substantial improvement in signal-to-noise ratio by using energy filtering to remove inelastically scattered electrons. This strategy results in sub-atomic resolution MicroED data from proteinase K crystals, enabling the visualization of detailed structural features. Interestingly, reducing the noise further reveals diffuse scattering that may hold additional structural information. Our findings suggest that combining energy filtering and direct detection provides more accurate measurements at higher resolution, facilitating precise model refinement and improved insights into protein structure and function.

Authors

Institutions

Publication Details

Journal
Nature Communications
Published
2025-03-06
DOI
https://doi.org/10.1038/s41467-025-57425-1
Citations
12
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
9.08

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy filtering enables macromolecular MicroED data at sub-atomic resolution

Johan Hattne, Max T. B. Clabbers, Michael W. Martynowycz, Tamir Gonen
12 citations
Nature Communications
Mass Spectrometry Techniques and Applications
9.08
article

Energy filtering enables macromolecular MicroED data at sub-atomic resolution

Johan Hattne, Max T. B. Clabbers, Michael W. Martynowycz, Tamir Gonen
article en
12 citations

Abstract

High-resolution information is important for accurate structure modeling but is challenging to attain in macromolecular crystallography due to the rapid fading of diffracted intensities at increasing resolution. While direct electron detection essentially eliminates the read-out noise during MicroED data collection, other sources of noise remain and limit the measurement of faint high-resolution reflections. Inelastic scattering significantly contributes to noise, raising background levels and broadening diffraction peaks. We demonstrate a substantial improvement in signal-to-noise ratio by using energy filtering to remove inelastically scattered electrons. This strategy results in sub-atomic resolution MicroED data from proteinase K crystals, enabling the visualization of detailed structural features. Interestingly, reducing the noise further reveals diffuse scattering that may hold additional structural information. Our findings suggest that combining energy filtering and direct detection provides more accurate measurements at higher resolution, facilitating precise model refinement and improved insights into protein structure and function.

Nature CommunicationsVol. 16(1)
Howard Hughes Medical Institute (US), University of California, Los Angeles (US)
U.S. Department of Defense, Howard Hughes Medical Institute, National Institutes of Health, Defense Threat Reduction Agency, National Institute of General Medical Sciences
Openalex Percentile: Top 2%
Mass Spectrometry Techniques and Applications
9.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.