Compatibility Analysis of Isotactic Polypropylene/Elastomer Blends for Power Cable Insulation Based on Numerical Simulations

ABSTRACT Using elastomers to toughen the isotactic polypropylene (iPP) for power cable insulation is an economically efficient and widely recognized method. However, the selection of elastomers mostly relies on experience, and the compatibility between iPP and elastomers lacks quantitative characterization. In this paper, molecular dynamics (MD) and mesoscopic dynamics (MesoDyn) simulations were used to analyze the compatibility between iPP and elastomers. The molecular weights of iPP and two types of elastomers, propylene‐based elastomer (PBE) and ethylene‐octene copolymer (EOC) were measured by Gel permeation chromatography (GPC) to obtain simulation parameters. Molecular and mesoscopic models of iPP/elastomer blends were established, and the compatibility between iPP and elastomers was analyzed according to the monomer, molecular chain, and aggregated structures. The results showed that the compatibility of iPP and PBE was higher than that of iPP and EOC. The mixing energy and interaction parameter of iPP/PBE were close to 0. The solubility parameters of iPP and PBE were approximate, and the binding energy of iPP/PBE was higher than that of iPP/EOC. The dispersion of PBE Gauss chains in the iPP matrix is better than that of EOC. With the increase of the elastomer content, the order parameter of the iPP/elastomer blend increased to above 0.1, from compatible system to incompatible system. The compatibility threshold of iPP/PBE was 20 wt% of the elastomer content, while that of iPP/EOC was 10 wt% of the elastomer content. The simulation results of the compatibility were closely related to the mechanical and electrical properties of the blends. It is suggested that the simulation method can provide a reference for the determination of the types and contents of elastomers in the investigation of iPP‐based cable insulation materials.

Authors

Institutions

Publication Details

Journal
Journal of Applied Polymer Science
Published
2025-02-26
DOI
https://doi.org/10.1002/app.56924
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compatibility Analysis of Isotactic Polypropylene/Elastomer Blends for Power Cable Insulation Based on Numerical Simulations

Ge Zheng, Jie Chen, Yu Gao, Jing Li et al.
Journal of Applied Polymer Science
High voltage insulation and dielectric phenomena
article

Compatibility Analysis of Isotactic Polypropylene/Elastomer Blends for Power Cable Insulation Based on Numerical Simulations

Ge Zheng, Jie Chen, Yu Gao, Jing Li, Xiaoyu Wang, Lingyun Gu, Yan Wu
article en

Abstract

ABSTRACT Using elastomers to toughen the isotactic polypropylene (iPP) for power cable insulation is an economically efficient and widely recognized method. However, the selection of elastomers mostly relies on experience, and the compatibility between iPP and elastomers lacks quantitative characterization. In this paper, molecular dynamics (MD) and mesoscopic dynamics (MesoDyn) simulations were used to analyze the compatibility between iPP and elastomers. The molecular weights of iPP and two types of elastomers, propylene‐based elastomer (PBE) and ethylene‐octene copolymer (EOC) were measured by Gel permeation chromatography (GPC) to obtain simulation parameters. Molecular and mesoscopic models of iPP/elastomer blends were established, and the compatibility between iPP and elastomers was analyzed according to the monomer, molecular chain, and aggregated structures. The results showed that the compatibility of iPP and PBE was higher than that of iPP and EOC. The mixing energy and interaction parameter of iPP/PBE were close to 0. The solubility parameters of iPP and PBE were approximate, and the binding energy of iPP/PBE was higher than that of iPP/EOC. The dispersion of PBE Gauss chains in the iPP matrix is better than that of EOC. With the increase of the elastomer content, the order parameter of the iPP/elastomer blend increased to above 0.1, from compatible system to incompatible system. The compatibility threshold of iPP/PBE was 20 wt% of the elastomer content, while that of iPP/EOC was 10 wt% of the elastomer content. The simulation results of the compatibility were closely related to the mechanical and electrical properties of the blends. It is suggested that the simulation method can provide a reference for the determination of the types and contents of elastomers in the investigation of iPP‐based cable insulation materials.

Journal of Applied Polymer ScienceVol. 142(21)
North China Electric Power University (CN), Tianjin University (CN), China Electric Power Research Institute
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 97%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.