Multidimensional-Constrained Suspect Screening of Hydrophobic Contaminants Using Gas Chromatography-Atmospheric Pressure Chemical Ionization-Ion Mobility-Mass Spectrometry

Suspect screening strives to rapidly monitor a large number of substances in a sample using mass spectral libraries. For hydrophobic organic contaminants (HOCs), these libraries are traditionally based on electron ionization mass spectra. However, with the growing use of state-of-the-art mass spectrometers, which often use alternative ionization approaches and separation techniques, new suspect screening workflows and libraries are urgently needed. This study established a new suspect screening library for 1,590 HOCs, including exact mass and a combination of measured and model-predicted values for retention time (RT) and collision cross section (CCS). The accuracy of <i>in silico</i> predictions was assessed using standards for 102 HOCs. Thereafter, using gas chromatography-atmospheric pressure chemical ionization-ion mobility-mass spectrometry, a suspect screening workflow constrained by the full scan mass spectrum of (quasi-)molecular ions (including isotope patterns), RT, CCS, and fragmentation mass spectra, together with a continuous scoring system, was established to reduce false positives and improve identification confidence. Application of the method to fortified and standard reference sediment samples demonstrated true positive rates of 79% and 64%, respectively, with all false positives attributed to suspect isomers. This study offers a new workflow for improved suspect screening of HOCs using multidimensional information and highlights the need to enrich mass spectral databases and extend the applicable chemical space of current <i>in silico</i> tools to hydrophobic substances.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-03-06
DOI
https://doi.org/10.1021/acs.analchem.4c06234
Citations
1
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multidimensional-Constrained Suspect Screening of Hydrophobic Contaminants Using Gas Chromatography-Atmospheric Pressure Chemical Ionization-Ion Mobility-Mass Spectrometry

Jonathan P. Benskin, Xiaodi Shi, Anna Sobek
1 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
0.76
article

Multidimensional-Constrained Suspect Screening of Hydrophobic Contaminants Using Gas Chromatography-Atmospheric Pressure Chemical Ionization-Ion Mobility-Mass Spectrometry

Jonathan P. Benskin, Xiaodi Shi, Anna Sobek
article en
1 citations

Abstract

Suspect screening strives to rapidly monitor a large number of substances in a sample using mass spectral libraries. For hydrophobic organic contaminants (HOCs), these libraries are traditionally based on electron ionization mass spectra. However, with the growing use of state-of-the-art mass spectrometers, which often use alternative ionization approaches and separation techniques, new suspect screening workflows and libraries are urgently needed. This study established a new suspect screening library for 1,590 HOCs, including exact mass and a combination of measured and model-predicted values for retention time (RT) and collision cross section (CCS). The accuracy of <i>in silico</i> predictions was assessed using standards for 102 HOCs. Thereafter, using gas chromatography-atmospheric pressure chemical ionization-ion mobility-mass spectrometry, a suspect screening workflow constrained by the full scan mass spectrum of (quasi-)molecular ions (including isotope patterns), RT, CCS, and fragmentation mass spectra, together with a continuous scoring system, was established to reduce false positives and improve identification confidence. Application of the method to fortified and standard reference sediment samples demonstrated true positive rates of 79% and 64%, respectively, with all false positives attributed to suspect isomers. This study offers a new workflow for improved suspect screening of HOCs using multidimensional information and highlights the need to enrich mass spectral databases and extend the applicable chemical space of current <i>in silico</i> tools to hydrophobic substances.

Analytical ChemistryVol. 97(10)
Stockholm University (SE)
Stockholms Universitet, HORIZON EUROPE Marie Sklodowska-Curie Actions
Openalex Percentile: Top 34%
Mass Spectrometry Techniques and Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.