Rapid urease test according to the rules and without

Quality control of endoscope processing is carried out in accordance with the requirements of the current sanitary legislation (1,2) within the framework of industrial control by instrumental and laboratory methods. The results of instrumental control entirely depend on the quality of the final cleaning of the endoscope by hand. The results of laboratory control are determined not only by the efficiency of the entire processing cycle, but also by the correctness of sampling and delivery to the microbiological laboratory. Interpretation of unsatisfactory results of microbiological control is very important. It includes searching for technical malfunctions, biological films and system errors in processing, if there are indications for this.

Authors

Institutions

Publication Details

Journal
Клиническая эндоскопия.
Published
2025-03-06
DOI
https://doi.org/10.31146/2415-7813-endo-66-4-66-70
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid urease test according to the rules and without

T. A. Grenkova
Клиническая эндоскопия.
Medical Device Sterilization and Disinfection
article

Rapid urease test according to the rules and without

T. A. Grenkova
article en

Abstract

Quality control of endoscope processing is carried out in accordance with the requirements of the current sanitary legislation (1,2) within the framework of industrial control by instrumental and laboratory methods. The results of instrumental control entirely depend on the quality of the final cleaning of the endoscope by hand. The results of laboratory control are determined not only by the efficiency of the entire processing cycle, but also by the correctness of sampling and delivery to the microbiological laboratory. Interpretation of unsatisfactory results of microbiological control is very important. It includes searching for technical malfunctions, biological films and system errors in processing, if there are indications for this.

Клиническая эндоскопия.Vol. 66(4)
Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing (RU)
Openalex Percentile: Top 96%
Medical Device Sterilization and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.