Interfractional body surface monitoring using daily cone-beam computed tomography imaging for pediatric adaptive proton therapy
The findings revealed that a 5 mm change in body surface can lead to a significant degradation of plan quality, reducing CTV D<sub>min</sub> by 11.7 % and underscoring the need for adapting treatment plan.
Authors
- Jinsoo Uh (ORCID: https://orcid.org/0000-0001-6837-8681)
- Thomas E. Merchant (ORCID: https://orcid.org/0000-0002-0412-6255)
- Chia‐Ho Hua (ORCID: https://orcid.org/0000-0002-6642-4004)
- Ozgur Ates (ORCID: https://orcid.org/0000-0003-2407-6184)
- Hoyeon Lee (ORCID: https://orcid.org/0000-0002-1165-1509)
- Matthew J. Krasin (ORCID: https://orcid.org/0000-0001-5421-765X)
Institutions
- St. Jude Children's Research Hospital (US)
Publication Details
- Journal
- Physics and Imaging in Radiation Oncology
- Published
- 2025-03-06
- DOI
- https://doi.org/10.1016/j.phro.2025.100746
- Citations
- 1
- Primary Topic
- Radiation Therapy and Dosimetry
- Type
- article
- Field-Weighted Citation Impact
- 1.52
Funders
- St. Jude Children's Research Hospital
- American Lebanese Syrian Associated Charities