Sub-Pixel Displacement Measurement with Swin Transformer: A Three-Level Classification Approach

In order to avoid the dependence of traditional sub-pixel displacement methods on interpolation method calculation, image gradient calculation, initial value estimation and iterative calculation, a Swin Transformer-based sub-pixel displacement measurement method (ST-SDM) is proposed, and a square dataset expansion method is also proposed to rapidly expand the training dataset. The ST-SDM computes sub-pixel displacement values of different scales through three-level classification tasks, and solves the problem of positive and negative displacement with the rotation relative tag value method. The accuracy of the ST-SDM is verified by simulation experiments, and its robustness is verified by real rigid body experiments. The experimental results show that the ST-SDM model has higher accuracy and higher efficiency than the comparison algorithm.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-03-06
DOI
https://doi.org/10.3390/app15052868
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sub-Pixel Displacement Measurement with Swin Transformer: A Three-Level Classification Approach

Zhixin Tie, Yongxing Lin, Xiaoyan Xu
1 citations
Applied Sciences
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
article

Sub-Pixel Displacement Measurement with Swin Transformer: A Three-Level Classification Approach

Zhixin Tie, Yongxing Lin, Xiaoyan Xu
article en
1 citations

Abstract

In order to avoid the dependence of traditional sub-pixel displacement methods on interpolation method calculation, image gradient calculation, initial value estimation and iterative calculation, a Swin Transformer-based sub-pixel displacement measurement method (ST-SDM) is proposed, and a square dataset expansion method is also proposed to rapidly expand the training dataset. The ST-SDM computes sub-pixel displacement values of different scales through three-level classification tasks, and solves the problem of positive and negative displacement with the rotation relative tag value method. The accuracy of the ST-SDM is verified by simulation experiments, and its robustness is verified by real rigid body experiments. The experimental results show that the ST-SDM model has higher accuracy and higher efficiency than the comparison algorithm.

Applied SciencesVol. 15(5)
Zhejiang Sci-Tech University (CN)
Openalex Percentile: Top 16%
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.