Modelling exposure to aerosols from showers: Implications for microbial risk assessment

• Aerosol generation and size distribution differ between cold showers and hot showers. • Aerosol concentrations generated during hot showers peak in the first two minutes. • Ventilation is more influential on aerosol removal for cold showers than for hot showers. • Accounting for dynamism in aerosol generation rates influences exposure estimates. Inhalation of aerosols produced during showering exposes people to chemical and microbial contaminants present in the water. To improve quantitative estimates of exposure and to inform the efficacy of potential interventions to reduce exposures, the number and size distributions of aerosols generated during showering events were monitored and a mass balance model of the generated aerosols was developed. The aerosol generation rates were calculated through calibrating the model with the measured aerosol data. Specifically, aerosol count concentrations and size distributions were measured with an aerodynamic particle sizer over the duration of mock showering events under various conditions, including different water temperatures and different showerhead types (conventional and rain showers). The empirical data were then used to fit a mass balance model to obtain aerosol generation rates and decay rates for each aerosol size class through least square fitting. An initial high peak concentration of aerosols was observed under hot water conditions relative to cold water conditions which resulted in a rapid increase in aerosol exposure during the first 1-2 minutes of showering. This suggests that people showering in hot water conditions will have a potentially increased exposure during the first 1-2 minutes. The model-fitted values suggest large inter-experiment variation in estimated aerosol generation and decay rates, even among triplicates of the same showering conditions. Current exposure assessment approaches assume constant aerosol concentrations during showers which might lead to miscalculated cumulative risk for microbial hazards because of their uneven distribution in building plumbing systems and biofilm detachment process during flushing. Thus, considering aerosol dynamics is beneficial during shower exposure assessments to inform risk management interventions. The data set and associated modeling results provided can support this, as they can be readily integrated into microbial risk assessments for waterborne pathogens such as Legionella spp., nontuberculous Mycobacteria (NTM) and Pseudomonas aeruginosa .

Authors

Institutions

Publication Details

Journal
Building and Environment
Published
2025-03-06
DOI
https://doi.org/10.1016/j.buildenv.2025.112825
Citations
2
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
3.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modelling exposure to aerosols from showers: Implications for microbial risk assessment

Frederik Hammes, Kerry A. Hamilton, Émile Sylvestre, Timothy R. Julian et al.
2 citations
Building and Environment
Infection Control and Ventilation
3.04
article

Modelling exposure to aerosols from showers: Implications for microbial risk assessment

Frederik Hammes, Kerry A. Hamilton, Émile Sylvestre, Timothy R. Julian, Franziska Böni, Lizhan Tang, Antonia Eichelberg
article en
2 citations

Abstract

• Aerosol generation and size distribution differ between cold showers and hot showers. • Aerosol concentrations generated during hot showers peak in the first two minutes. • Ventilation is more influential on aerosol removal for cold showers than for hot showers. • Accounting for dynamism in aerosol generation rates influences exposure estimates. Inhalation of aerosols produced during showering exposes people to chemical and microbial contaminants present in the water. To improve quantitative estimates of exposure and to inform the efficacy of potential interventions to reduce exposures, the number and size distributions of aerosols generated during showering events were monitored and a mass balance model of the generated aerosols was developed. The aerosol generation rates were calculated through calibrating the model with the measured aerosol data. Specifically, aerosol count concentrations and size distributions were measured with an aerodynamic particle sizer over the duration of mock showering events under various conditions, including different water temperatures and different showerhead types (conventional and rain showers). The empirical data were then used to fit a mass balance model to obtain aerosol generation rates and decay rates for each aerosol size class through least square fitting. An initial high peak concentration of aerosols was observed under hot water conditions relative to cold water conditions which resulted in a rapid increase in aerosol exposure during the first 1-2 minutes of showering. This suggests that people showering in hot water conditions will have a potentially increased exposure during the first 1-2 minutes. The model-fitted values suggest large inter-experiment variation in estimated aerosol generation and decay rates, even among triplicates of the same showering conditions. Current exposure assessment approaches assume constant aerosol concentrations during showers which might lead to miscalculated cumulative risk for microbial hazards because of their uneven distribution in building plumbing systems and biofilm detachment process during flushing. Thus, considering aerosol dynamics is beneficial during shower exposure assessments to inform risk management interventions. The data set and associated modeling results provided can support this, as they can be readily integrated into microbial risk assessments for waterborne pathogens such as Legionella spp., nontuberculous Mycobacteria (NTM) and Pseudomonas aeruginosa .

Building and EnvironmentVol. 275
Swiss Tropical and Public Health Institute (CH), University of Basel (CH), Center for Environmental Health (US), ETH Zurich (CH), Arizona State University (US), Swiss Federal Institute of Aquatic Science and Technology (CH)
Bundesamt für Gesundheit, Bundesamt für Lebensmittelsicherheit und Veterinärwesen, Bundesamt für Energie
Openalex Percentile: Top 11%
Infection Control and Ventilation
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.