Multivariate Gaussian Bayes classifier with limited data for segmentation of clean and contaminated regions in the small bowel capsule endoscopy images

A considerable amount of undesirable factors in the wireless capsule endoscopy (WCE) procedure hinder the proper visualization of the small bowel and take gastroenterologists more time to review. Objective quantitative assessment of different bowel preparation paradigms and saving the physician reviewing time motivated us to present an automatic low-cost statistical model for automatically segmenting of clean and contaminated regions in the WCE images. In the model construction phase, only 20 manually pixel-labeled images have been used from the normal and reduced mucosal view classes of the Kvasir capsule endoscopy dataset. In addition to calculating prior probability, two different probabilistic tri-variate Gaussian distribution models (GDMs) with unique mean vectors and covariance matrices have been fitted to the concatenated RGB color pixel intensity values of clean and contaminated regions separately. Applying the Bayes rule, the membership probability of every pixel of the input test image to each of the two classes is evaluated. The robustness has been evaluated using 5 trials; in each round, from the total number of 2000 randomly selected images, 20 and 1980 images have been used for model construction and evaluation modes, respectively. Our experimental results indicate that accuracy, precision, specificity, sensitivity, area under the receiver operating characteristic curve (AUROC), dice similarity coefficient (DSC), and intersection over union (IOU) are 0.89 ± 0.07, 0.91 ± 0.07, 0.73 ± 0.20, 0.90 ± 0.12, 0.92 ± 0.06, 0.92 ± 0.05 and 0.86 ± 0.09, respectively. The presented scheme is easy to deploy for objectively assessing small bowel cleansing score, comparing different bowel preparation paradigms, and decreasing the inspection time. The results from the SEE-AI project dataset and CECleanliness database proved that the proposed scheme has good adaptability.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-03-07
DOI
https://doi.org/10.1371/journal.pone.0315638
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multivariate Gaussian Bayes classifier with limited data for segmentation of clean and contaminated regions in the small bowel capsule endoscopy images

Alireza Mehridehnavi, Vahid Sadeghi, Alireza Vard, Mohsen Sharifi et al.
1 links
PLoS ONE
Gastrointestinal Bleeding Diagnosis and Treatment
article

Multivariate Gaussian Bayes classifier with limited data for segmentation of clean and contaminated regions in the small bowel capsule endoscopy images

Alireza Mehridehnavi, Vahid Sadeghi, Alireza Vard, Mohsen Sharifi, Niloufar Teyfouri, Yasaman Sanahmadi, Maryam Behdad, Mina Omrani
article en

Abstract

A considerable amount of undesirable factors in the wireless capsule endoscopy (WCE) procedure hinder the proper visualization of the small bowel and take gastroenterologists more time to review. Objective quantitative assessment of different bowel preparation paradigms and saving the physician reviewing time motivated us to present an automatic low-cost statistical model for automatically segmenting of clean and contaminated regions in the WCE images. In the model construction phase, only 20 manually pixel-labeled images have been used from the normal and reduced mucosal view classes of the Kvasir capsule endoscopy dataset. In addition to calculating prior probability, two different probabilistic tri-variate Gaussian distribution models (GDMs) with unique mean vectors and covariance matrices have been fitted to the concatenated RGB color pixel intensity values of clean and contaminated regions separately. Applying the Bayes rule, the membership probability of every pixel of the input test image to each of the two classes is evaluated. The robustness has been evaluated using 5 trials; in each round, from the total number of 2000 randomly selected images, 20 and 1980 images have been used for model construction and evaluation modes, respectively. Our experimental results indicate that accuracy, precision, specificity, sensitivity, area under the receiver operating characteristic curve (AUROC), dice similarity coefficient (DSC), and intersection over union (IOU) are 0.89 ± 0.07, 0.91 ± 0.07, 0.73 ± 0.20, 0.90 ± 0.12, 0.92 ± 0.06, 0.92 ± 0.05 and 0.86 ± 0.09, respectively. The presented scheme is easy to deploy for objectively assessing small bowel cleansing score, comparing different bowel preparation paradigms, and decreasing the inspection time. The results from the SEE-AI project dataset and CECleanliness database proved that the proposed scheme has good adaptability.

PLoS ONEVol. 20(3)
Yazd University (IR), Isfahan University of Medical Sciences (IR), Amirkabir University of Technology (IR)
Openalex Percentile: Top 94%
Gastrointestinal Bleeding Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.