Improved Field-Weakening Control of PM Motors for Home Appliances Excluding Speed Loop Windup

Field-weakening (FW) operating mode is an essential function of high-performance permanent magnet (PM) motor drives, which helps to overcome limitation of speed due to the lack of input voltage, thus increasing drives’ speed operational region. Therefore, one of the algorithms for FW is a crucial part of the overwhelmingness majority of PM motor control systems. The most popular FW approach is a feedback technique, however it is computationally intensive and may demonstrate speed loop windup. In order to eliminate abovementioned disadvantages, this article proposes optimization for fast computing of FW controller and modifications to the conventional feedback FW controller, which exclude speed loop windup. The suggested optimizations exclude square root calculations and decrease computational cycles ten times. The proposed antiwindup technique dynamically recalculates limits for speed controller, considering FW current calculated by the FW controller. These improvements provide speed loop antiwindup operation, simplify structure of the resulting control scheme, decreases system reaction time and computational burden on the microcontrollers, which is extremely important to low-cost motor drives.

Authors

Institutions

Publication Details

Journal
IEEE/ASME Transactions on Mechatronics
Published
2025-03-06
DOI
https://doi.org/10.1109/tmech.2025.3543279
Citations
8
Primary Topic
Sensorless Control of Electric Motors
Type
article
Field-Weighted Citation Impact
5.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Field-Weakening Control of PM Motors for Home Appliances Excluding Speed Loop Windup

Anton Dianov
8 citations
IEEE/ASME Transactions on Mechatronics
Sensorless Control of Electric Motors
5.84
article

Improved Field-Weakening Control of PM Motors for Home Appliances Excluding Speed Loop Windup

Anton Dianov
article en
8 citations

Abstract

Field-weakening (FW) operating mode is an essential function of high-performance permanent magnet (PM) motor drives, which helps to overcome limitation of speed due to the lack of input voltage, thus increasing drives’ speed operational region. Therefore, one of the algorithms for FW is a crucial part of the overwhelmingness majority of PM motor control systems. The most popular FW approach is a feedback technique, however it is computationally intensive and may demonstrate speed loop windup. In order to eliminate abovementioned disadvantages, this article proposes optimization for fast computing of FW controller and modifications to the conventional feedback FW controller, which exclude speed loop windup. The suggested optimizations exclude square root calculations and decrease computational cycles ten times. The proposed antiwindup technique dynamically recalculates limits for speed controller, considering FW current calculated by the FW controller. These improvements provide speed loop antiwindup operation, simplify structure of the resulting control scheme, decreases system reaction time and computational burden on the microcontrollers, which is extremely important to low-cost motor drives.

IEEE/ASME Transactions on MechatronicsVol. 30(6)
Wenzhou University (CN)
Affordable and clean energy
Openalex Percentile: Top 4%
Sensorless Control of Electric Motors
5.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.