A Hybrid Near-Far Field Channel Model for RIS-Assisted Healthcare Monitoring and Precision Positioning in Internet of Everything

Recent advancements in wireless communications have revolutionized healthcare delivery through Internet of Everything (IoE) connectivity, yet achieving precise medical device positioning and reliable patient monitoring remains a fundamental challenge. As communication frequencies increase and reconfigurable intelligent surface (RIS) apertures expand in healthcare settings, the operating conditions gradually transition from traditional far-field (FF) radiation patterns to near-field (NF) scenarios. This article proposes a healthcare channel hybrid model (HCHM) framework that seamlessly integrates NF and FF characteristics. The weighting factor adapts dynamically according to the ratio of near-field to FF route gains, facilitating appropriate tradeoffs between positioning precision and monitoring coverage. We present a complete channel model tailored for healthcare IoE applications by incorporating an adaptive weighting factor that accounts for the proximity and placement needs of medical devices. Based on 10000 Monte Carlo simulations in a typical hospital environment (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$30\times 30$ </tex-math></inline-formula> RIS array, 100-MHz bandwidth, 2–200 m monitoring range), with 95% confidence intervals, HCHM achieves positioning accuracies of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.3~\pm ~0.02$ </tex-math></inline-formula> mm in critical care scenarios while maintaining reliable patient monitoring across extended distances. Simulation results demonstrate that HCHM achieves significant improvements in system performance and model robustness, with positioning accuracy enhanced by 45% and monitoring reliability improved by 42% compared to conventional approaches, making it particularly suitable for next-generation healthcare IoE applications.

Authors

Institutions

Publication Details

Journal
IEEE Internet of Things Journal
Published
2025-03-06
DOI
https://doi.org/10.1109/jiot.2025.3548840
Citations
2
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Hybrid Near-Far Field Channel Model for RIS-Assisted Healthcare Monitoring and Precision Positioning in Internet of Everything

Haitao Chu, Yue Wu, Hongxu Zhou, Ma Xiaodi
2 citations
IEEE Internet of Things Journal
Wireless Body Area Networks
1.35
article

A Hybrid Near-Far Field Channel Model for RIS-Assisted Healthcare Monitoring and Precision Positioning in Internet of Everything

Haitao Chu, Yue Wu, Hongxu Zhou, Ma Xiaodi
article en
2 citations

Abstract

Recent advancements in wireless communications have revolutionized healthcare delivery through Internet of Everything (IoE) connectivity, yet achieving precise medical device positioning and reliable patient monitoring remains a fundamental challenge. As communication frequencies increase and reconfigurable intelligent surface (RIS) apertures expand in healthcare settings, the operating conditions gradually transition from traditional far-field (FF) radiation patterns to near-field (NF) scenarios. This article proposes a healthcare channel hybrid model (HCHM) framework that seamlessly integrates NF and FF characteristics. The weighting factor adapts dynamically according to the ratio of near-field to FF route gains, facilitating appropriate tradeoffs between positioning precision and monitoring coverage. We present a complete channel model tailored for healthcare IoE applications by incorporating an adaptive weighting factor that accounts for the proximity and placement needs of medical devices. Based on 10000 Monte Carlo simulations in a typical hospital environment (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$30\times 30$ </tex-math></inline-formula> RIS array, 100-MHz bandwidth, 2–200 m monitoring range), with 95% confidence intervals, HCHM achieves positioning accuracies of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.3~\pm ~0.02$ </tex-math></inline-formula> mm in critical care scenarios while maintaining reliable patient monitoring across extended distances. Simulation results demonstrate that HCHM achieves significant improvements in system performance and model robustness, with positioning accuracy enhanced by 45% and monitoring reliability improved by 42% compared to conventional approaches, making it particularly suitable for next-generation healthcare IoE applications.

IEEE Internet of Things JournalVol. 12(13)
First Hospital of China Medical University (CN), China Medical University (CN)
Openalex Percentile: Top 22%
Wireless Body Area Networks
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.