A Flexible Compensation Control Strategy for High-Frequency Link Matrix Converters

High-frequency link matrix converters (HFLMCs) omit a dc-link capacitor, which can achieve power transmission from dc to ac with only one power converter stage. However, due to the core shift and vibration, parameter perturbation usually occurs in the isolated high-frequency transformer (IHFT) of the HFLMC, which threatens its safety. This article proposes a flexible compensation control strategy for HFLMC. A rotary IHFT is designed, and the transmission power and current stress on the IHFT of HFLMC under the symmetrical SVM strategy are analyzed. The designed IHFT can comprehensively simulate the parameter perturbation caused by core shift and vibration, and the proposed control strategy can reduce power fluctuation and the current stress on the IHFT of the HFLMC. Simulation and experiment are conducted, and the results validate the effectiveness of the proposed control strategy.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Electronics
Published
2025-03-06
DOI
https://doi.org/10.1109/tie.2025.3544218
Citations
3
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
2.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Flexible Compensation Control Strategy for High-Frequency Link Matrix Converters

Yujing Guo, Ping Jin, Junjie Liu, Gang Lei et al.
3 citations
IEEE Transactions on Industrial Electronics
Advanced DC-DC Converters
2.19
article

A Flexible Compensation Control Strategy for High-Frequency Link Matrix Converters

Yujing Guo, Ping Jin, Junjie Liu, Gang Lei, Jianguo G. Zhu, Yunqing Hu
article en
3 citations

Abstract

High-frequency link matrix converters (HFLMCs) omit a dc-link capacitor, which can achieve power transmission from dc to ac with only one power converter stage. However, due to the core shift and vibration, parameter perturbation usually occurs in the isolated high-frequency transformer (IHFT) of the HFLMC, which threatens its safety. This article proposes a flexible compensation control strategy for HFLMC. A rotary IHFT is designed, and the transmission power and current stress on the IHFT of HFLMC under the symmetrical SVM strategy are analyzed. The designed IHFT can comprehensively simulate the parameter perturbation caused by core shift and vibration, and the proposed control strategy can reduce power fluctuation and the current stress on the IHFT of the HFLMC. Simulation and experiment are conducted, and the results validate the effectiveness of the proposed control strategy.

IEEE Transactions on Industrial ElectronicsVol. 72(9)
University of Technology Sydney (AU), The University of Sydney (AU), Hohai University (CN)
Openalex Percentile: Top 13%
Advanced DC-DC Converters
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.