Volume self-calibration for three-dimensional particle tracking velocimetry based on a stereoscopic shadowgraph system

Abstract The stereoscopic shadowgraph system can accommodate high framing rate, long depth of field, and high imaging quality for two-phase flow measurements. The system has been combined with three-dimensional (3D) particle tracking velocimetry (PTV) to implement time-resolved volumetric measurements. Due to inadequate constraints, the calibration residuals and system drift can cause deviations of the mapping function, leading to a large proportion of ghost particles. In this study, the extrinsic parameters self-calibration (EPSC) based on particle images is introduced to correct the mapping function error. The algorithm is implemented by minimizing the reprojection disparity, where the drift is transferred to the right camera by fixing the left camera as reference. Synthetic datasets are used to evaluate the influence of drifts and self-calibration algorithms on PTV processes within a wide range of 0.0039–0.0625 ppp particle image densities. The extrinsic parameters including both translation and rotation drifts are involved and the effect of sub-domain divisions during rotation drift is discussed. Results indicate that the deviated mapping functions greatly impact the accuracy of the 3D tracking process, and the EPSC algorithm can significantly reduce the reprojection error and the proportion of ghost particles. For translation drift between 0.57 and 1.13 pixels, more than 95% of true particles are tracked and the proportion of ghost particles is below 5% after EPSC process. For rotation drift with approximately a maximum 2 pixels disparity, the EPSC can also restore more than 95% and 55% true particles for the two datasets respectively. The current method is applied to the 3D flow field of an oscillating foil in still water, based on which reasonable particle trajectories are successfully resolved. The results indicate that the EPSC algorithm can effectively reduce the influence of system drift and improve the tracking accuracy of two-view PTV measurements. The current method has the potential to enable two-view volumetric PTV techniques to cope with scenarios of denser particle concentrations and achieve higher spatial resolution.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-03-06
DOI
https://doi.org/10.1088/1361-6501/adbd60
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Volume self-calibration for three-dimensional particle tracking velocimetry based on a stereoscopic shadowgraph system

Qian Wang, Changying Zhao, Xiaohan Mei, Jinwu Wei
Measurement Science and Technology
Optical measurement and interference techniques
article

Volume self-calibration for three-dimensional particle tracking velocimetry based on a stereoscopic shadowgraph system

Qian Wang, Changying Zhao, Xiaohan Mei, Jinwu Wei
article en

Abstract

Abstract The stereoscopic shadowgraph system can accommodate high framing rate, long depth of field, and high imaging quality for two-phase flow measurements. The system has been combined with three-dimensional (3D) particle tracking velocimetry (PTV) to implement time-resolved volumetric measurements. Due to inadequate constraints, the calibration residuals and system drift can cause deviations of the mapping function, leading to a large proportion of ghost particles. In this study, the extrinsic parameters self-calibration (EPSC) based on particle images is introduced to correct the mapping function error. The algorithm is implemented by minimizing the reprojection disparity, where the drift is transferred to the right camera by fixing the left camera as reference. Synthetic datasets are used to evaluate the influence of drifts and self-calibration algorithms on PTV processes within a wide range of 0.0039–0.0625 ppp particle image densities. The extrinsic parameters including both translation and rotation drifts are involved and the effect of sub-domain divisions during rotation drift is discussed. Results indicate that the deviated mapping functions greatly impact the accuracy of the 3D tracking process, and the EPSC algorithm can significantly reduce the reprojection error and the proportion of ghost particles. For translation drift between 0.57 and 1.13 pixels, more than 95% of true particles are tracked and the proportion of ghost particles is below 5% after EPSC process. For rotation drift with approximately a maximum 2 pixels disparity, the EPSC can also restore more than 95% and 55% true particles for the two datasets respectively. The current method is applied to the 3D flow field of an oscillating foil in still water, based on which reasonable particle trajectories are successfully resolved. The results indicate that the EPSC algorithm can effectively reduce the influence of system drift and improve the tracking accuracy of two-view PTV measurements. The current method has the potential to enable two-view volumetric PTV techniques to cope with scenarios of denser particle concentrations and achieve higher spatial resolution.

Measurement Science and TechnologyVol. 36(4)
Shanghai Jiao Tong University (CN)
National Natural Science Foundation of China, Australian Research Council
Openalex Percentile: Top 97%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.