Operation performance of a ground source heat pump system in the mediterranean climate zone. First results

Abstract This paper presents the configuration and performance of a Low Enthalpy Geothermal System successfully installed and utilized in the Mediterranean climate zone. Additionally, it examines the performance of different types of Ground Heat Exchangers (GHE), all installed in the same System. The Ground Source Heat Pump (GSHP) of the system consists of vertical ground heat exchangers (GHEs) in five different configurations, one double helicoidal coil in a well and an open loop (well) system. The entire system is constantly monitored by a Building Management System (BMS) that records the energy, volume flow, incoming and outgoing temperature at critical points of the system. Based on the recorded values, the performance of the System was analyzed in a heating and a cooling working mode, after examining the power flows in and out from critical points of the System. Results show higher heat exchange values inside the open well, both in heating and cooling mode suggesting the usage of this type of GHE, where applicable. Additionally, the electric power consumed by the chillers which are the largest electricity consumers within the System, is approximately five times lower than the power placed in the building by the Geothermal System (SCOP between 4.5 and 5). In terms of primary energy savings, we can say with confidence the GSHP systems working under Mediterranean climate zone conditions, can be consider as high efficiency solutions, verifying the theoretical efficiency given by the manufacturer of the GSHP.

Authors

Institutions

Publication Details

Journal
Energy Efficiency
Published
2025-03-01
DOI
https://doi.org/10.1007/s12053-025-10307-3
Citations
2
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operation performance of a ground source heat pump system in the mediterranean climate zone. First results

Lazaros Aresti, Iosifina I. Stylianou, Georgios A. Florides, Paul Christodoulides et al.
2 citations
Energy Efficiency
Geothermal Energy Systems and Applications
0.73
article

Operation performance of a ground source heat pump system in the mediterranean climate zone. First results

Lazaros Aresti, Iosifina I. Stylianou, Georgios A. Florides, Paul Christodoulides, C. T. Christou
article en
2 citations

Abstract

Abstract This paper presents the configuration and performance of a Low Enthalpy Geothermal System successfully installed and utilized in the Mediterranean climate zone. Additionally, it examines the performance of different types of Ground Heat Exchangers (GHE), all installed in the same System. The Ground Source Heat Pump (GSHP) of the system consists of vertical ground heat exchangers (GHEs) in five different configurations, one double helicoidal coil in a well and an open loop (well) system. The entire system is constantly monitored by a Building Management System (BMS) that records the energy, volume flow, incoming and outgoing temperature at critical points of the system. Based on the recorded values, the performance of the System was analyzed in a heating and a cooling working mode, after examining the power flows in and out from critical points of the System. Results show higher heat exchange values inside the open well, both in heating and cooling mode suggesting the usage of this type of GHE, where applicable. Additionally, the electric power consumed by the chillers which are the largest electricity consumers within the System, is approximately five times lower than the power placed in the building by the Geothermal System (SCOP between 4.5 and 5). In terms of primary energy savings, we can say with confidence the GSHP systems working under Mediterranean climate zone conditions, can be consider as high efficiency solutions, verifying the theoretical efficiency given by the manufacturer of the GSHP.

Energy EfficiencyVol. 18(3)
Cyprus University of Technology (CY)
Cyprus University of Technology, Research and Innovation Foundation
Openalex Percentile: Top 33%
Geothermal Energy Systems and Applications
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Operation performance of a ground source heat pump system in the mediterranean climate zone. First results — Lazaros Aresti, Iosifina I. Stylianou, et al. · Energy Efficiency (2025) | TGRS Research Map | TGRS