Photonic crystal with a defect layer of silicon containing polymer nanocomposites as radiation detector

This paper presents a photonic crystal-based gamma radiation detector featuring a defect layer of silicon embedded with polymer nanocomposites. The transfer matrix method is utilized as a computational tool to evaluate the transmittance properties of the proposed detector. The study investigates the effects of cell count and porosity on the detector's performance. The model can accurately and simultaneously distinguish between different gamma radiation doses by observing changes in the refractive index of the active layer. The detector demonstrates high sensitivity, with 0.804 nm/Gy for doses ranging from 0 to 100 Gy and 0.225 nm/Gy for doses between 100 and 200 Gy. The proposed model, incorporating porous silicon and ethylene oxide polymer nanocomposites, exhibits exceptional performance as a gamma radiation sensor.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-07
DOI
https://doi.org/10.1038/s41598-025-91050-8
Citations
9
Primary Topic
Photonic Crystals and Applications
Type
article
Field-Weighted Citation Impact
11.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photonic crystal with a defect layer of silicon containing polymer nanocomposites as radiation detector

Mohammed Sallah, В. Д. Жакетов, Zaky A. Zaky, С. В. Кожевников
9 citations
Scientific Reports
Photonic Crystals and Applications
11.22
article

Photonic crystal with a defect layer of silicon containing polymer nanocomposites as radiation detector

Mohammed Sallah, В. Д. Жакетов, Zaky A. Zaky, С. В. Кожевников
article en
9 citations

Abstract

This paper presents a photonic crystal-based gamma radiation detector featuring a defect layer of silicon embedded with polymer nanocomposites. The transfer matrix method is utilized as a computational tool to evaluate the transmittance properties of the proposed detector. The study investigates the effects of cell count and porosity on the detector's performance. The model can accurately and simultaneously distinguish between different gamma radiation doses by observing changes in the refractive index of the active layer. The detector demonstrates high sensitivity, with 0.804 nm/Gy for doses ranging from 0 to 100 Gy and 0.225 nm/Gy for doses between 100 and 200 Gy. The proposed model, incorporating porous silicon and ethylene oxide polymer nanocomposites, exhibits exceptional performance as a gamma radiation sensor.

Scientific ReportsVol. 15(1)
Beni-Suef University (EG), Moscow Institute of Physics and Technology (RU), Joint Institute for Nuclear Research (RU), Academy of Scientific Research and Technology (EG), University of Bisha (SA)
Openalex Percentile: Top 1%
Photonic Crystals and Applications
11.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.