EVALUATION OF RELIABILITY OF PANORAMIC RADIOGRAPH IN LOCALIZATION OF LABIO-PALATAL POSITION OF MAXILLARY IMPACTED CANINE: A RETROSPECTIVE STUDY

The current study was directed towards comparing the labio-palatal position of maxillary impacted canine on panoramic radiograph and trying to locate any reliable angular-linear measurement to determine the labio-palatal position of the impacted tooth. 60 cone-beam computed tomography x-rays were used for the same cases, 30 with buccal impacted canine and 30 with palatal impacted canine to identify each case whether it is buccaly impacted or palatal. In the present study 6 measurements were specified on the panoramic radiograph (3 angular- 1 linear- 2 sectors) to compare it to the actual impaction site (through the CBCT) of the impacted canines and examine their reliability in determining the actual impaction site. From the selected 6 measurements that have been worked on, there were no significant point found to be reliable for defining the exact labio-palatal position of maxillary impacted canines. Based on the results of the present study, it was concluded that; panoramic radiograph is not reliable for localization of the labiopalatal position of the maxillary impacted canine through the chosen linear and angular measurements was tested on this study.

Authors

Institutions

Publication Details

Journal
Dental Science Updates /Dental Science Updates
Published
2025-03-01
DOI
https://doi.org/10.21608/dsu.2025.293228.1238
Primary Topic
dental development and anomalies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATION OF RELIABILITY OF PANORAMIC RADIOGRAPH IN LOCALIZATION OF LABIO-PALATAL POSITION OF MAXILLARY IMPACTED CANINE: A RETROSPECTIVE STUDY

Walaa el gemaey, Ahmed Samir Barakat, Hanady mohamed samih, asmaa abdallah
Dental Science Updates /Dental Science Updates
dental development and anomalies
article

EVALUATION OF RELIABILITY OF PANORAMIC RADIOGRAPH IN LOCALIZATION OF LABIO-PALATAL POSITION OF MAXILLARY IMPACTED CANINE: A RETROSPECTIVE STUDY

Walaa el gemaey, Ahmed Samir Barakat, Hanady mohamed samih, asmaa abdallah
article en

Abstract

The current study was directed towards comparing the labio-palatal position of maxillary impacted canine on panoramic radiograph and trying to locate any reliable angular-linear measurement to determine the labio-palatal position of the impacted tooth. 60 cone-beam computed tomography x-rays were used for the same cases, 30 with buccal impacted canine and 30 with palatal impacted canine to identify each case whether it is buccaly impacted or palatal. In the present study 6 measurements were specified on the panoramic radiograph (3 angular- 1 linear- 2 sectors) to compare it to the actual impaction site (through the CBCT) of the impacted canines and examine their reliability in determining the actual impaction site. From the selected 6 measurements that have been worked on, there were no significant point found to be reliable for defining the exact labio-palatal position of maxillary impacted canines. Based on the results of the present study, it was concluded that; panoramic radiograph is not reliable for localization of the labiopalatal position of the maxillary impacted canine through the chosen linear and angular measurements was tested on this study.

Dental Science Updates /Dental Science UpdatesVol. 6(1)
Suez Canal University (EG)
Openalex Percentile: Top 96%
dental development and anomalies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.