Fabrication of Radiopaque, Drug-Loaded Resorbable Polymer for Medical Device Development

Resorbable medical devices provide temporary functionality before degrading into safe byproducts. One application is absorbable inferior vena cava filters (IVCFs), which prevent pulmonary embolism in high-risk patients with contraindications to anticoagulants. However, current absorbable IVCFs are limited by radiolucency and local clot formation risks. This study aimed to develop radiopaque, drug-loaded resorbable IVCFs with enhanced imaging and therapeutic capabilities. Poly-p-dioxanone (PPDO) sutures were infused with gadolinium nanoparticles (GdNPs) and dipyridamole (DPA), an anti-thrombotic agent. GdNPs were synthesized with an average diameter of 35.76 ± 3.71 nm. Gd content was 371 ± 1.6 mg/g (PPDO-Gd) and 280 ± 0.3 mg/g (PPDO-Gd + DPA), while the DPA content was 18.20 ± 5.38 mg/g (PPDO-DPA) and 12.91 ± 0.83 mg/g (PPDO-Gd + DPA). Suture thickness (0.39-0.49 cm, <i>p</i> = 0.0143) and melting temperature (103.61-105.90, <i>p</i> = 0.0002) statistically differed among the different groups, while load-at-break did not (4.39-5.38, <i>p</i> = 0.2367). Although suture thickness and melting temperatures differed significantly, load-at-break was preserved and did not alter the mechanical and degradation properties of the various IVCFs. Micro-computed tomography revealed enhanced radiopacity for Gd-containing IVCFs (2713 ± 105 HU for PPDO-Gd, 1516 ± 281 HU for PPDO-Gd + DPA). Radiopacity decreased gradually over 10-12 weeks. Clot-trapping efficacy was maintained, and no hemolysis or cellular toxicity was observed. In conclusion, the GdNP- and DPA-infused PPDO IVCFs demonstrated improved radiopacity, anti-thrombotic potential, and compatibility with routine imaging, without compromising mechanical strength or safety.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2025-03-07
DOI
https://doi.org/10.3390/polym17060716
Citations
4
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
7.48
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication of Radiopaque, Drug-Loaded Resorbable Polymer for Medical Device Development

Archana Mishra, Steven Y. Huang, Marvin R. Bernardino, Megan C. Jacobsen et al.
4 citations
Polymers
Venous Thromboembolism Diagnosis and Management
7.48
article

Fabrication of Radiopaque, Drug-Loaded Resorbable Polymer for Medical Device Development

Archana Mishra, Steven Y. Huang, Marvin R. Bernardino, Megan C. Jacobsen, Gino Martin Canlas, Gouthami Chintalapani, Erin Marie D. San Valentin, Dominic Karl M. Bolinas, Allan John R. Barcena, S. Melançon
article en
4 citations

Abstract

Resorbable medical devices provide temporary functionality before degrading into safe byproducts. One application is absorbable inferior vena cava filters (IVCFs), which prevent pulmonary embolism in high-risk patients with contraindications to anticoagulants. However, current absorbable IVCFs are limited by radiolucency and local clot formation risks. This study aimed to develop radiopaque, drug-loaded resorbable IVCFs with enhanced imaging and therapeutic capabilities. Poly-p-dioxanone (PPDO) sutures were infused with gadolinium nanoparticles (GdNPs) and dipyridamole (DPA), an anti-thrombotic agent. GdNPs were synthesized with an average diameter of 35.76 ± 3.71 nm. Gd content was 371 ± 1.6 mg/g (PPDO-Gd) and 280 ± 0.3 mg/g (PPDO-Gd + DPA), while the DPA content was 18.20 ± 5.38 mg/g (PPDO-DPA) and 12.91 ± 0.83 mg/g (PPDO-Gd + DPA). Suture thickness (0.39-0.49 cm, <i>p</i> = 0.0143) and melting temperature (103.61-105.90, <i>p</i> = 0.0002) statistically differed among the different groups, while load-at-break did not (4.39-5.38, <i>p</i> = 0.2367). Although suture thickness and melting temperatures differed significantly, load-at-break was preserved and did not alter the mechanical and degradation properties of the various IVCFs. Micro-computed tomography revealed enhanced radiopacity for Gd-containing IVCFs (2713 ± 105 HU for PPDO-Gd, 1516 ± 281 HU for PPDO-Gd + DPA). Radiopacity decreased gradually over 10-12 weeks. Clot-trapping efficacy was maintained, and no hemolysis or cellular toxicity was observed. In conclusion, the GdNP- and DPA-infused PPDO IVCFs demonstrated improved radiopacity, anti-thrombotic potential, and compatibility with routine imaging, without compromising mechanical strength or safety.

PolymersVol. 17(6)
The University of Texas MD Anderson Cancer Center (US), Lamar University (US), Siemens Healthcare (United States) (US), University of the Philippines Manila (PH)
Good health and well-being
Openalex Percentile: Top 3%
Venous Thromboembolism Diagnosis and Management
7.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.