Deep learning approaches for continuous blood pressure estimation from photoplethysmography signal

Monitoring continuous Blood Pressure (BP) signals is essential as BP can vary rapidly. However, current Photoplethysmography (PPG)-based methods for estimating BP need to be more accurate and provide predictions for Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP). Full cycle of PPG waveform is considered to estimate SBP and DBP values. This study recommends deep learning techniques, including Temporal Convolutional Network (TCN), Long-Short Term Memory (LSTM), TCN-LSTM, and Autoencoder-LSTM, to estimate SBP and DBP. According to the outcomes, the proposed framework estimates continuous BP precisely utilising PPG signals. Specifically, the Autoencoder-LSTM algorithm achieved a Mean Average Error (MAE) of 1.05 and 0.92 for SBP and DBP and a Standard Deviation (SD) of 1.89 and 1.05 for SBP and DBP, respectively, indicating that the model is suitable for estimating these values from PPG signals. The Autoencoder-LSTM approach produced a Mean Average Error (MAE) of 1.05 and 0.92 for SBP and DBP, respectively, as well as a Standard Deviation (SD) of 1.89 and 1.05, demonstrating that the model can estimate these values using PPG signals. This paper evaluates an algorithm that estimates BP continuously using the PPG signal. Autoencoder-LSTM is suitable for estimating continuous BP values since MAE and SD values are low for SBP and DBP.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2025-03-05
DOI
https://doi.org/10.1016/j.measen.2025.101866
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep learning approaches for continuous blood pressure estimation from photoplethysmography signal

R. Vanithamani, Sri Jayabharathi S, S. Pavithra, S. E.
2 citations
Measurement Sensors
Non-Invasive Vital Sign Monitoring
1.35
article

Deep learning approaches for continuous blood pressure estimation from photoplethysmography signal

R. Vanithamani, Sri Jayabharathi S, S. Pavithra, S. E.
article en
2 citations

Abstract

Monitoring continuous Blood Pressure (BP) signals is essential as BP can vary rapidly. However, current Photoplethysmography (PPG)-based methods for estimating BP need to be more accurate and provide predictions for Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP). Full cycle of PPG waveform is considered to estimate SBP and DBP values. This study recommends deep learning techniques, including Temporal Convolutional Network (TCN), Long-Short Term Memory (LSTM), TCN-LSTM, and Autoencoder-LSTM, to estimate SBP and DBP. According to the outcomes, the proposed framework estimates continuous BP precisely utilising PPG signals. Specifically, the Autoencoder-LSTM algorithm achieved a Mean Average Error (MAE) of 1.05 and 0.92 for SBP and DBP and a Standard Deviation (SD) of 1.89 and 1.05 for SBP and DBP, respectively, indicating that the model is suitable for estimating these values from PPG signals. The Autoencoder-LSTM approach produced a Mean Average Error (MAE) of 1.05 and 0.92 for SBP and DBP, respectively, as well as a Standard Deviation (SD) of 1.89 and 1.05, demonstrating that the model can estimate these values using PPG signals. This paper evaluates an algorithm that estimates BP continuously using the PPG signal. Autoencoder-LSTM is suitable for estimating continuous BP values since MAE and SD values are low for SBP and DBP.

Measurement SensorsVol. 39
Avinashilingam University (IN)
Openalex Percentile: Top 22%
Non-Invasive Vital Sign Monitoring
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Deep learning approaches for continuous blood pressure estimation from photoplethysmography signal — R. Vanithamani, Sri Jayabharathi S, et al. · Measurement Sensors (2025) | TGRS Research Map | TGRS