Dimensions Define Stability: Insertion Torque of Orthodontic Mini-Implants: A Comparative In Vitro Study

<b>Background</b>: Mini-implants have transformed orthodontic treatment by providing reliable anchorage and addressing challenges in anchorage control. This in vitro study aimed to compare the insertion torque (IT) values of three types of orthodontic mini-implants. The null hypothesis stated that no significant difference would be found in IT based on mini-implant type. <b>Methods</b>: We analyzed the mechanical ITs of 12 mini-implants categorized into four groups based on lengths (6, 8, 10, and 12 mm) and diameters (1.4, 1.6, and 2.0 mm). Mini-implants were inserted at a 90° angle into artificial bone (Sawbones<sup>®</sup>) without pre-drilling. The ANOVA and Tukey's post hoc test assessed differences, and Spearman's correlation evaluated relationships between IT, diameter, and length. <b>Results</b>: The Lomas Mondefit<sup>®</sup> 2 × 8 mm mini-implant had the highest IT (35 N), while the Jeil 2 × 12 mm had the lowest. Torque correlated with diameter (ρ = 0.609, <i>p</i> = 0.047) and length (ρ = 0.890, <i>p</i> < 0.001). The ANOVA showed significant differences (<i>p</i> = 0.035), with Leone<sup>®</sup> and Lomas Mondefit<sup>®</sup> differing significantly (<i>p</i> = 0.029). Mini-implant dimensions strongly influence IT. <b>Conclusions</b>: Mini-implant diameter and length significantly influence IT, highlighting their importance in clinical applications for optimal stability and performance.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-03-05
DOI
https://doi.org/10.3390/jcm14051752
Citations
4
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
6.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dimensions Define Stability: Insertion Torque of Orthodontic Mini-Implants: A Comparative In Vitro Study

Cristian Romanec, Tinela Panaite, Irina Zetu
4 citations
Journal of Clinical Medicine
Orthodontics and Dentofacial Orthopedics
6.70
article

Dimensions Define Stability: Insertion Torque of Orthodontic Mini-Implants: A Comparative In Vitro Study

Cristian Romanec, Tinela Panaite, Irina Zetu
article en
4 citations

Abstract

<b>Background</b>: Mini-implants have transformed orthodontic treatment by providing reliable anchorage and addressing challenges in anchorage control. This in vitro study aimed to compare the insertion torque (IT) values of three types of orthodontic mini-implants. The null hypothesis stated that no significant difference would be found in IT based on mini-implant type. <b>Methods</b>: We analyzed the mechanical ITs of 12 mini-implants categorized into four groups based on lengths (6, 8, 10, and 12 mm) and diameters (1.4, 1.6, and 2.0 mm). Mini-implants were inserted at a 90° angle into artificial bone (Sawbones<sup>®</sup>) without pre-drilling. The ANOVA and Tukey's post hoc test assessed differences, and Spearman's correlation evaluated relationships between IT, diameter, and length. <b>Results</b>: The Lomas Mondefit<sup>®</sup> 2 × 8 mm mini-implant had the highest IT (35 N), while the Jeil 2 × 12 mm had the lowest. Torque correlated with diameter (ρ = 0.609, <i>p</i> = 0.047) and length (ρ = 0.890, <i>p</i> < 0.001). The ANOVA showed significant differences (<i>p</i> = 0.035), with Leone<sup>®</sup> and Lomas Mondefit<sup>®</sup> differing significantly (<i>p</i> = 0.029). Mini-implant dimensions strongly influence IT. <b>Conclusions</b>: Mini-implant diameter and length significantly influence IT, highlighting their importance in clinical applications for optimal stability and performance.

Journal of Clinical MedicineVol. 14(5)
Grigore T. Popa University of Medicine and Pharmacy (RO)
Openalex Percentile: Top 4%
Orthodontics and Dentofacial Orthopedics
6.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dimensions Define Stability: Insertion Torque of Orthodontic Mini-Implants: A Comparative In Vitro Study — Cristian Romanec, Tinela Panaite, et al. · Journal of Clinical Medicine (2025) | TGRS Research Map | TGRS