To the Issue of Assessment of the Technical Condition of Underground Structures of Buildings

A survey and assessment of the technical condition of basement and semi-basement structures in public buildings aged 60 to 130 years were conducted to evaluate their suitability for use as basic shelters. Based on the survey results, the most adverse impacts were identified, including changes in groundwater levels, improper building operation, and the characteristic damages to underground structural elements. Structural solutions were proposed to eliminate the consequences of these damages. The reviewed cases indicate that the vertical and horizontal waterproofing systems used during construction cannot perform their function throughout the building’s entire life cycle. When designing new buildings, waterproof materials should be used for the enclosing structures of underground premises. While this may have a higher initial cost than membrane or coating waterproofing, considering life-cycle costs, it can provide a positive economic effect and improve the quality and comfort of the indoor environment.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-03-05
DOI
https://doi.org/10.3390/su17052264
Citations
1
Primary Topic
Underground infrastructure and sustainability
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

To the Issue of Assessment of the Technical Condition of Underground Structures of Buildings

Nataliia Mahas, Adriana Salles, Volodymyr Semko, Oleksandr Semko et al.
1 citations
Sustainability
Underground infrastructure and sustainability
1.01
article

To the Issue of Assessment of the Technical Condition of Underground Structures of Buildings

Nataliia Mahas, Adriana Salles, Volodymyr Semko, Oleksandr Semko, Олена Філоненко, Yuriy Vynnykov, Roman Rabenseifer, Oleg Yurin, Ricardo Mateus, L. Bragança, Olena Hranko, Tetiana Ilchenko
article en
1 citations

Abstract

A survey and assessment of the technical condition of basement and semi-basement structures in public buildings aged 60 to 130 years were conducted to evaluate their suitability for use as basic shelters. Based on the survey results, the most adverse impacts were identified, including changes in groundwater levels, improper building operation, and the characteristic damages to underground structural elements. Structural solutions were proposed to eliminate the consequences of these damages. The reviewed cases indicate that the vertical and horizontal waterproofing systems used during construction cannot perform their function throughout the building’s entire life cycle. When designing new buildings, waterproof materials should be used for the enclosing structures of underground premises. While this may have a higher initial cost than membrane or coating waterproofing, considering life-cycle costs, it can provide a positive economic effect and improve the quality and comfort of the indoor environment.

SustainabilityVol. 17(5)
Slovak University of Technology in Bratislava (SK), National University "Yuri Kondratyuk Poltava Polytechnic" (UA), Poznań University of Technology (PL), Adam Mickiewicz University in Poznań (PL), University of Minho (PT)
Openalex Percentile: Top 27%
Underground infrastructure and sustainability
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.