Development, validation, acceptability and usability of a device-based system to measure sit-stand desk usage

We describe the development and testing (across three studies) of an open-source device designed to measure sit-stand desk usage: the Desk Positioning System (DPS). Accuracy of the DPS was assessed under prescribed (Study 1) and free-living (Study 2; video criterion) conditions, across multiple desk-types. Study 3 assessed usability and acceptability in the short-term (1-week) and longer-term (5-weeks). RESULTS: In Study 1, the DPS was 100% accurate at identifying most conditions (presence at desk 59/72 conditions, detecting desk height 166/168). In Study 2 (n = 10) the DPS demonstrated high accuracy (F1>0.95) and precision (>0.98) against the criterion (7866 observations). Study 3 participants (n = 23) reported high device acceptability in both the short- (mean [sd] 4.4/5 [SD 0.4]) and longer-term (4.6/5 [0.5]). Usability was above the 68-score industry benchmark at the short- (72.4/100 [14.2]) and longer-term (74.7/100 [18.5]). CONCLUSION: The DPS may provide an accurate, acceptable and useable way of understanding sit-stand desk usage.

Authors

Institutions

Publication Details

Journal
Applied Ergonomics
Published
2025-03-02
DOI
https://doi.org/10.1016/j.apergo.2025.104490
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development, validation, acceptability and usability of a device-based system to measure sit-stand desk usage

Bronwyn Clark, Alejandro Melendez-Calderon, George Thomas, Genevieve Nissa Healy et al.
Applied Ergonomics
Ergonomics and Musculoskeletal Disorders
article

Development, validation, acceptability and usability of a device-based system to measure sit-stand desk usage

Bronwyn Clark, Alejandro Melendez-Calderon, George Thomas, Genevieve Nissa Healy, Yue Cheng, Noah Bongers, Sami A. Kaab, Katherine A. Heseltine
article en

Abstract

We describe the development and testing (across three studies) of an open-source device designed to measure sit-stand desk usage: the Desk Positioning System (DPS). Accuracy of the DPS was assessed under prescribed (Study 1) and free-living (Study 2; video criterion) conditions, across multiple desk-types. Study 3 assessed usability and acceptability in the short-term (1-week) and longer-term (5-weeks). RESULTS: In Study 1, the DPS was 100% accurate at identifying most conditions (presence at desk 59/72 conditions, detecting desk height 166/168). In Study 2 (n = 10) the DPS demonstrated high accuracy (F1>0.95) and precision (>0.98) against the criterion (7866 observations). Study 3 participants (n = 23) reported high device acceptability in both the short- (mean [sd] 4.4/5 [SD 0.4]) and longer-term (4.6/5 [0.5]). Usability was above the 68-score industry benchmark at the short- (72.4/100 [14.2]) and longer-term (74.7/100 [18.5]). CONCLUSION: The DPS may provide an accurate, acceptable and useable way of understanding sit-stand desk usage.

Applied ErgonomicsVol. 126
Queensland Health (AU), Australian Research Council (AU), Queensland University of Technology (AU), The University of Queensland (AU)
Openalex Percentile: Top 96%
Ergonomics and Musculoskeletal Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development, validation, acceptability and usability of a device-based system to measure sit-stand desk usage — Bronwyn Clark, Alejandro Melendez-Calderon, et al. · Applied Ergonomics (2025) | TGRS Research Map | TGRS